| 11847.1 |
1.0 Snap Lock |
1.0 Snap Lock 24GA over 19/32" or greater APA rated plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-131 Other: -67.3 PSF @ 24" o.c.
-131.0 PSF @ 24" o.c.
Install per manufacturer's details. For use in compliance with Current FBC .1x4 SYP may be applied over plywood substrate. Fastener to penetrate thru plywood 3/8" |
Installation Instructions FL11847_R6_II_FL 11847 METAL ROOF FACTORY INSTALL DETAILS.pdf FL11847_R6_II_FL 11847 METAL ROOF FACTORY.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL11847_R6_AE_FL 11847 METAL ROOF FACTORY.pdf Created by Independent Third Party: Yes |
|
|
| 11847.2 |
5V Crimp |
26 Ga. 5V Crimp Roof Panel over APA Rated Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-156.5PSF Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf @ 6" o.c. fastener spacing. Install per manufacturers details. For use in HVHZ Zones in compliance with Current FBC. 1x4 SYP may be applied over plywood substrate. Fastener to penetrate thru plywood 3/8" |
Installation Instructions FL11847_R6_II_FL 11847 METAL ROOF FACTORY INSTALL DETAILS.pdf FL11847_R6_II_FL 11847 METAL ROOF FACTORY.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL11847_R6_AE_FL 11847 METAL ROOF FACTORY.pdf Created by Independent Third Party: Yes |
|
|
| 11847.3 |
Mechanical Lock |
1 1/2" Mechanical Lock 24 Ga. 16" wide over APA Rated Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5PSF Other: -59.75 psf @ 24” O.C. Clip Spacing. -123.5 psf @ 6” O.C. Clip Spacing. Install per manufacturers details. For use in HVHZ Zones in compliance with Current FBC .1x4 SYP may be applied over plywood substrate. Fastener to penetrate thru plywood 3/8"
|
Installation Instructions FL11847_R6_II_FL 11847 METAL ROOF FACTORY INSTALL DETAILS.pdf FL11847_R6_II_FL 11847 METAL ROOF FACTORY.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL11847_R6_AE_FL 11847 METAL ROOF FACTORY.pdf Created by Independent Third Party: Yes |
|
|
| 11847.4 |
Nail Strip |
1” Nailstrip 24 Ga. 16” Wide over 15/32” APA Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5PSF Other: -59.75 psf @ 16” O.C. fastener spacing in panel slots. -101.0 psf @ 6 3/4” O.C. fastener spacing in panel slots. -153.5 psf @ 6 3/4” O.C. fastener in slot & 12” O.C. 1x4 SYP may be applied over plywood substrate. Fastener to penetrate thru plywood 3/8"fasteners in Pan (See Details)Install per manufacturers details. Not for use in HVHZ Zones.1x4 SYP may be applied over plywood substrate. Fastener to penetrate thru plywood 3/8" |
Installation Instructions FL11847_R6_II_FL 11847 METAL ROOF FACTORY INSTALL DETAILS.pdf FL11847_R6_II_FL 11847 METAL ROOF FACTORY.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL11847_R6_AE_FL 11847 METAL ROOF FACTORY.pdf Created by Independent Third Party: Yes |
|
|
| 11847.5 |
Rib |
26 Ga. Rib over 15/32” APA Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-146.0PSF Other: -69.25 psf @ 24” O.C. Fastener Pattern Type A. -146.0 psf @ 12" O.C. Fastener Pattern Type B. Install per manufacturers details.1x4 SYP may be applied over plywood substrate. Fastener to penetrate thru plywood 3/8" |
Installation Instructions FL11847_R6_II_FL 11847 METAL ROOF FACTORY INSTALL DETAILS.pdf FL11847_R6_II_FL 11847 METAL ROOF FACTORY.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL11847_R6_AE_FL 11847 METAL ROOF FACTORY.pdf Created by Independent Third Party: Yes |
|
|
| 11847.6 |
Snap Lock |
1 1/2" Snap Lock 24 Ga. and 0.032 AL Snap Lock over APA Rated Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0PSF Other: HVHZ panel 24GA-86.0 psf @ 24” O.C. Clip Spacing. -108.5 psf @ 12” O.C. Clip Spacing. -116.0 psf @ 6” O.C. Clip Spacing. Non HVHZ AL panel -45psf@16"o.c., -52psf@6"o.c. Install per manufacturers details. For use in compliance with FBC .1x4 SYP may be applied over plywood substrate. Fastener to penetrate thru plywood 3/8" |
Installation Instructions FL11847_R6_II_FL 11847 METAL ROOF FACTORY INSTALL DETAILS.pdf FL11847_R6_II_FL 11847 METAL ROOF FACTORY.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL11847_R6_AE_FL 11847 METAL ROOF FACTORY.pdf Created by Independent Third Party: Yes |