Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL6332-R13
Application Type Revision
Code Version 2023
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer ICP Construction, Inc.
Address/Phone/Email 2775 Barber Road
Norton, OH 44203
(330) 753-4585   Ext 1108
mkeen@icpgroup.com
 
Authorized Signature Mark Keen
mkeen@icpgroup.com
 
Technical Representative Mark Keen
Address/Phone/Email 2775 barber rd
Norton, OH 44203
(330) 753-4585   Ext 1108
mkeen@icpgroup.com
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Roof Tile Adhesives
 
Compliance Method Evaluation Report from a Product Evaluation Entity
 
Evaluation Entity NEMO CERT, LLC (Eval)
Quality Assurance Entity NEMO CERT, LLC (INSPECT)
Quality Assurance Contract Expiration Date 12/31/2030
Validated By NEMO CERT, LLC (Validation)
 
 
Certificate of Independence FL6332_R13_COI_2024_07_COI_NEMO.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM D16212010
ASTM D16222020
ASTM D16232017
ASTM D21262020
ASTM D28422019
ASTM D28561998
ASTM E962016
SSTD 111997
TAS 1011995
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option C
 
Date Submitted 08/29/2025
Date Validated 08/29/2025
Date Pending FBC Approval
Date Approved 09/01/2025
 
Summary of Products
FL # Model, Number or Name Description
6332.1 APOC POLYSET AH-160 Dual component expanding polyurethane roof tile adhesive for use in FBC non-HVHZ and HVHZ jurisdictions.
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +n/a/-178
 Other: 1.) The design pressure limitation in this application refers to hip and ridge tiles in one configuration. Refer to NER Table 3 for all hip and ridge tile limitations. 2.) Field tiles are designed based on overturning moment resistance. Refer to NER Table 2 for field tile limitations. 3.) Refer to NER Section 4 for other Limitations of Use.
Installation Instructions
 FL6332_R13_II_2025_08_29_FINAL_NER-ICP-001.R1_FL6332-R13.pdf
 Verified By: NEMO CERT, LLC (Eval)
 Created by Independent Third Party: 
Evaluation Reports
 FL6332_R13_AE_2025_08_29_FINAL_NER-ICP-001.R1_FL6332-R13.pdf
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex