| 2030.1 |
Dryvit Outsulation Plus MD |
Exterior Insulation and Finish System with Drainage over 1/2" Sheathing |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: For limits of use, see NOA#22-0914.09 |
Installation Instructions FL2030_R14_II_2030.1-Dryvit Outsulation and outsulation Plus MD over Glass Mat Gyp.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL2030_R14_AE_2030.1-Dryvit Outsulation and outsulation Plus MD over Glass Mat Gyp.pdf |
|
|
| 2030.2 |
Dryvit Outsulation Plus MD |
Exterior Insulation and Finish System over 5/8", 5 ply plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +100/-100 Other: For limits of use, see NOA#22-0914.11 |
Installation Instructions FL2030_R14_II_2030.2-Dryvit Outsulation Plus MD over Plywood.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL2030_R14_AE_2030.2-Dryvit Outsulation Plus MD over Plywood.pdf |
|
|
| 2030.3 |
Dryvit Outsulation X |
Outsulation X EIF System over 5/8" Gypsum Sheathing |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +93/-93 Other: For limits of use, see NOA#22-0914.10 |
Installation Instructions FL2030_R14_II_2030.3-Dryvit Outsulation X over Gyp.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL2030_R14_AE_2030.3-Dryvit Outsulation X over Gyp.pdf |
|
|
| 2030.4 |
Dryvit Outsulation/Outsulation Plus MD System |
Exterior Insulation and Finish System over 1/2" Sheathing for walls less than 30 feet |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: For limits of use, see NOA#22-0914.09 |
Installation Instructions FL2030_R14_II_2030.4-Dryvit Outsulation and Outsulation Plus MD over Glass Mat Gyp.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL2030_R14_AE_2030.4-Dryvit Outsulation and Outsulation Plus MD over Glass Mat Gyp.pdf |
|
|
| 2030.5 |
Dryvit Outsulation/Outsulation Plus MD System |
Outsulation and Outsulation Plus MD with Panzer 20 EIF Systems over 5/8" Gypsum Sheathing. Screw attachment 6" oc |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +110/-110 Other: For limits of use, see NOA#22-0914.16 |
Installation Instructions FL2030_R14_II_2030.5-Dryvit Outsulation and Outsulation Plus MD with Panzer 20 over Gyp.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL2030_R14_AE_2030.5-Dryvit Outsulation and Outsulation Plus MD with Panzer 20 over Gyp.pdf |
|
|
| 2030.6 |
Dryvit Outsulation/Outsulation Plus MD System |
Outsulation and Outsulation Plus MD with Panzer 20 EIF Systems over 5/8" Gypsum Sheathing. Screw attachment 6" oc |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +135/-135 Other: For limits of use, see NOA#22-0914.17 |
Installation Instructions FL2030_R14_II_2030.6 Dryvit Outsulation and Outsulation Plus MD with Panzer 20 over Gyps.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL2030_R14_AE_2030.6 Dryvit Outsulation and Outsulation Plus MD with Panzer 20 over Gyps.pdf |
|
|
| 2030.7 |
Dryvit Outsulation/Outsulation Plus MD System |
Exterior Insulation and Finish System over 5/8" Sheathing for walls less than 30 feet |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +135/-155 Other: For limits of use, see NOA#22-0914.17 |
Installation Instructions FL2030_R14_II_2030.7- Dryvit Outsulation and Outsulation Plus MD with Panzer 20 over Gyp.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL2030_R14_AE_2030.7- Dryvit Outsulation and Outsulation Plus MD with Panzer 20 over Gyp.pdf |
|
|
| 2030.8 |
Dryvit Outsulation/Outsulation Plus MD System |
Exterior Insulation and Finish System over 5/8" Sheathing for walls above 30 feet |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +93/-93 Other: For limits of use, see NOA#22-0914.15 |
Installation Instructions FL2030_R14_II_2030.8-Dryvit Outsulation and Outsulation Plus MD over Gyp.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL2030_R14_AE_2030.8-Dryvit Outsulation and Outsulation Plus MD over Gyp.pdf |
|
|
| 2030.9 |
Dryvit Outsulation/Outsulation Plus MD System |
Exterior Insulation and Finish System over Concrete or Concrete Masonry |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +160/-160 Other: For limits of use, see NOA#22-0225.01 |
Installation Instructions FL2030_R14_II_2030.9-Dryvit Outsulation and Outsulation Plus MD over Concrete.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL2030_R14_AE_2030.9-Dryvit Outsulation and Outsulation Plus MD over Concrete.pdf |
|
|
| 2030.10 |
Dryvit Outsulaton Plus MD |
Exterior Insulation and Finish System with Drainage over 5/8" Sheathing for walls less than 30 feet |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +106/-106 Other: For limits of use, see NOA22-0914.13 |
Installation Instructions FL2030_R14_II_2030.10-Dryvit Outsulation Plus MD with Standard Plus EIFS over Gyp.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL2030_R14_AE_2030.10-Dryvit Outsulation Plus MD with Standard Plus EIFS over Gyp.pdf |