Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL14996-R12
Application Type Revision
Code Version 2023
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Silver Line Building Products Corp.
Address/Phone/Email 5020 Weston Parkway
Cary, NC 27513
(614) 307-3278
luanne.harris@cornerstone-bb.com
 
Authorized Signature Luanne Harris
luanne.harris@cornerstone-bb.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Windows
Subcategory Double Hung
 
Compliance Method Certification Mark or Listing
 
Certification Agency National Accreditation & Management Institute
Validated By National Accreditation & Management Institute
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA/CSA101/I.S.2/A4402011
ASTM E 18862019
ASTM E 19962020
TAS 2011994
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL14996_R12_Equiv_FL14996 Equivalancy Statement.pdf
 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 02/03/2025
Date Validated 02/11/2025
Date Pending FBC Approval
Date Approved 02/12/2025
 
Summary of Products
FL # Model, Number or Name Description
14996.1 V1 Series/50 Series (1200) Double-Hung Window
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: N/A
 Other: See Installation Instructions and Product Evaluation Report for allowable design pressures, sizes, installation requirements and limits of use.
Certification Agency Certificate
 FL14996_R12_C_CAC_NI016438.01.pdf
 FL14996_R12_C_CAC_NI016438.02.pdf
 FL14996_R12_C_CAC_NI016438.pdf
Quality Assurance Contract Expiration Date
 12/31/2028
Installation Instructions
 FL14996_R12_II_SWD031-D.pdf
 Verified By: Hermes F. Norero, P.E. Florida P.E. 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14996_R12_AE_PER9637.pdf
 Created by Independent Third Party: Yes
14996.2 V3 Series/70 Series (3000/3900) Double-Hung Window
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: N/A
 Other: See Installation Instructions and Product Evaluation Report for allowable design pressures, sizes, installation requirements and limits of use.
Certification Agency Certificate
 FL14996_R12_C_CAC_NI016437.01.pdf
 FL14996_R12_C_CAC_NI016437.02.pdf
 FL14996_R12_C_CAC_NI016437.03.pdf
 FL14996_R12_C_CAC_NI016437.04.pdf
 FL14996_R12_C_CAC_NI016437.05.pdf
 FL14996_R12_C_CAC_NI016437.06.pdf
 FL14996_R12_C_CAC_NI016437.07.pdf
 FL14996_R12_C_CAC_NI016437.08.pdf
 FL14996_R12_C_CAC_NI016437.09.pdf
 FL14996_R12_C_CAC_NI016437.10.pdf
 FL14996_R12_C_CAC_NI016437.11.pdf
 FL14996_R12_C_CAC_NI016437.12.pdf
 FL14996_R12_C_CAC_NI016437.13.pdf
 FL14996_R12_C_CAC_NI016437.15.pdf
 FL14996_R12_C_CAC_NI016437.pdf
Quality Assurance Contract Expiration Date
 12/31/2028
Installation Instructions
 FL14996_R12_II_SWD032-D.pdf
 Verified By: Hermes F. Norero, P.E. Florida P.E. 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14996_R12_AE_PER9638.pdf
 Created by Independent Third Party: Yes
14996.3 V3 Series/70 Series (3600) Double-Hung Window
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: See Installation Instructions and Product Evaluation Report for allowable design pressures, sizes, installation requirements and limits of use.
Certification Agency Certificate
 FL14996_R12_C_CAC_NI016439.01.pdf
Quality Assurance Contract Expiration Date
 12/31/2028
Installation Instructions
 FL14996_R12_II_SWD035-E.pdf
 Verified By: Hermes F. Norero, P.E. Florida P.E. 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14996_R12_AE_PER9639.pdf
 Created by Independent Third Party: Yes
14996.4 V3 Series/70 Series (8600) Double-Hung Window
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: N/A
 Other: See Installation Instructions and Product Evaluation Report for allowable design pressures, sizes, installation requirements and limits of use.
Certification Agency Certificate
 FL14996_R12_C_CAC_NI016440.01.pdf
 FL14996_R12_C_CAC_NI016440.pdf
Quality Assurance Contract Expiration Date
 12/31/2028
Installation Instructions
 FL14996_R12_II_SWD033-D.pdf
 Verified By: Hermes F. Norero, P.E. Florida P.E. 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14996_R12_AE_PER9640.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts: