| 22226.1 |
Mech-Seam Standing Seam Roof Panel |
26 Ga. Mech-Seam Standing Seam Roof Panel, 14" wide over open framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-26.0 psf Other: -26.0 psf @ 5'-0” O.C. Clip Spacing. See evaluation report for additional design pressures. Install per manufacturer's details. Not for use in HVHZ Zones.
|
Installation Instructions FL22226_R2_II_22226.1 Mech Seam Structural Roof Panel NON HVHZ_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL22226_R2_AE_22226.1 Mech Seam Structural Roof Panel NON HVHZ_sealed.pdf Created by Independent Third Party: Yes |
|
|
| 22226.2 |
Mech-Seam Standing Seam Roof Panel |
24 Ga. Mech-Seam Standing Seam Roof Panel, 18" wide over open framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-36.4 psf Other: -36.4 psf @ 5'-0” O.C. Clip Spacing. See evaluation report for additional design pressures. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL22226_R2_II_22226.2 Mech Seam Structural Roof Panel NON HVHZ_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL22226_R2_AE_22226.2 Mech Seam Structural Roof Panel NON HVHZ_sealed.pdf Created by Independent Third Party: Yes |