| 17996.1 |
Series 202-20S Steel Door |
Series 202-20S Steel O.S. Door w/ Vertical Slider Window |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +38.7/-32 Other: |
Certification Agency Certificate FL17996_R4_C_CAC_Elixir - 202-20S OS Door (1b) ASTM June 2024 (ext.5).pdf Quality Assurance Contract Expiration Date 07/11/2029 Installation Instructions FL17996_R4_II_ELIX0034 Rev B Model 202-20S_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996_R4_AE_PER_1642_Rev4_ss.pdf Created by Independent Third Party: Yes |
|
|
| 17996.2 |
Series 230 W9 Steel Door |
Series 230 W9 Steel O.S. Door w/ Cottage Window |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25.3/-25.3 Other: |
Certification Agency Certificate FL17996_R4_C_CAC_Elixir - 230-W9 OS Door (1b) ASTM June 2024 (ext.5).pdf Quality Assurance Contract Expiration Date 07/11/2029 Installation Instructions FL17996_R4_II_ELIX0033 Rev B Model 230 W9_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996_R4_AE_PER_1642_Rev4_ss.pdf Created by Independent Third Party: Yes |
|
|
| 17996.3 |
Series 402-14 |
Vinyl Steel Out-Swinging Regular Door - 14" x 14" Window |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +66/-56 Other: |
Certification Agency Certificate FL17996_R4_C_CAC_Elixir - 402-14 OS Door (1b) ASTM June 2024 (ext.5).pdf Quality Assurance Contract Expiration Date 08/26/2030 Installation Instructions FL17996_R4_II_ELIX0050 REV-B OS MODEL 402-14_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996_R4_AE_PER_1951_Rev4_ss.pdf Created by Independent Third Party: Yes |
|
|
| 17996.4 |
Series 402-20S |
Vinyl Steel Out-swinging Regular Door - 20" slider window |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +66/-56 Other: |
Certification Agency Certificate FL17996_R4_C_CAC_Elixir - 402-20S OS Door (1b) ASTM June 2024 (ext.5).pdf Quality Assurance Contract Expiration Date 08/26/2030 Installation Instructions FL17996_R4_II_ELIX0051 REV-B OS MODEL 402-20S_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996_R4_AE_PER_1951_Rev4_ss.pdf Created by Independent Third Party: Yes |
|
|
| 17996.5 |
Series 407 |
Vinyl Steel Out-Swing Regular Door - Blank (no window) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: |
Certification Agency Certificate FL17996_R4_C_CAC_Elixir - 407 OS Door (1b) ASTM June 2024 (ext.5).pdf Quality Assurance Contract Expiration Date 08/19/2030 Installation Instructions FL17996_R4_II_ELIX0052 REV-B OS MODEL 407_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996_R4_AE_PER_1951_Rev4_ss.pdf Created by Independent Third Party: Yes |
|
|
| 17996.6 |
Series 430 W9 |
Vinyl Steel Out-swinging Regular Door - 9-Lite Window (1'8"
x 3'0") |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: |
Certification Agency Certificate FL17996_R4_C_CAC_Elixir - 430-W9 OS Door (1b) ASTM June 2024 (ext.5).pdf Quality Assurance Contract Expiration Date 08/25/2030 Installation Instructions FL17996_R4_II_ELIX0053 REV-B OS MODEL 430-W9_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996_R4_AE_PER_1951_Rev4_ss.pdf Created by Independent Third Party: Yes |
|
|
| 17996.7 |
Series 6400 W9 Cottage |
Series 6400-W9 Non-Impact Inswing Painted Steel Door
w/Storm Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +66.7/-56.7 Other: |
Certification Agency Certificate FL17996_R4_C_CAC_Elixir - 6400-W9 IS Door w-Storm (1b) ASTM June 2024 (ext.5).pdf Quality Assurance Contract Expiration Date 09/07/2029 Installation Instructions FL17996_R4_II_ELIX0056 Rev-B IS MODEL 6400-W9 WITH STORM DOOR_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996_R4_AE_PER_1954_Rev4_ss.pdf Created by Independent Third Party: Yes |
|
|
| 17996.8 |
Series 7500 Oval |
Series 7500 Non-Impact Inswing Vinyl Laminated Steel Door
w/Storm Door and PVC Jambs |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: |
Certification Agency Certificate FL17996_R4_C_CAC_Elixir - 7500 IS Door w-Storm (1b) ASTM June 2024 (ext.5).pdf Quality Assurance Contract Expiration Date 08/23/2029 Installation Instructions FL17996_R4_II_ELIX0060 Rev-B IS MODEL STR 7500 OVAL WITH STORM DOOR_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996_R4_AE_PER_1955_Rev4_ss.pdf Created by Independent Third Party: Yes |
|
|
| 17996.9 |
Series 8400 W9 Cottage |
Series 8400-W9 Non-Impact Oval Inswing Vinyl Laminated
Steel Door w/Storm Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: |
Certification Agency Certificate FL17996_R4_C_CAC_Elixir - 8400-W9 IS Door w-Storm (1b) ASTM June 2024 (ext.5).pdf Quality Assurance Contract Expiration Date 09/07/2029 Installation Instructions FL17996_R4_II_ELIX0057 Rev-B IS MODEL 8400-W9 OVAL WITH STORM DOOR_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996_R4_AE_PER_1954_Rev4_ss.pdf Created by Independent Third Party: Yes |
|
|
| 17996.10 |
Series 9000 |
Series 9000 Non-Impact Inswing Vinyl Laminated Steel Door
w/Storm Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50.7 Other: |
Certification Agency Certificate FL17996_R4_C_CAC_Elixir - 9000 IS Door w-Storm (1b) ASTM June 2024 (ext.5).pdf Quality Assurance Contract Expiration Date 09/06/2029 Installation Instructions FL17996_R4_II_ELIX0058 Rev-B IS BLANK 9000 DOOR W. STORM DOOR_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996_R4_AE_PER_1954_Rev4_ss.pdf Created by Independent Third Party: Yes |
|
|
| 17996.11 |
Series 9400-W9 Cottage |
Series 9400-W9 Non-Impact Inswing Vinyl Laminated Steel Door w/Storm Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: |
Certification Agency Certificate FL17996_R4_C_CAC_Elixir - 9400-W9 IS Door w-Storm (1b) ASTM June 2024 (ext.5).pdf Quality Assurance Contract Expiration Date 09/06/2029 Installation Instructions FL17996_R4_II_ELIX0059 Rev-B IS MODEL 9400-W9 COTTAGE W. STORM DOOR_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996_R4_AE_PER_1954_Rev4_ss.pdf Created by Independent Third Party: Yes |
|
|
| 17996.12 |
Series AFIF7N |
Series AFIF7N Non-Impact IS Fiberglass Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +38.7/-38.7 Other: |
Certification Agency Certificate FL17996_R4_C_CAC_Elixir - AFIF7N IS Door (1b) ASTM June 2024 (ext.5).pdf Quality Assurance Contract Expiration Date 08/21/2029 Installation Instructions FL17996_R4_II_ELIX0040 AFIF7N-BFIF7N_RevB_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996_R4_AE_PER_1952_Rev4_ss.pdf Created by Independent Third Party: Yes |
|
|
| 17996.13 |
Series AVIF7N |
Series AVIF7N Non-Impact IS Steel Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +38/-38 Other: |
Certification Agency Certificate FL17996_R4_C_CAC_Elixir - AVIF7N IS Door (1b) ASTM June 2024 (ext.5).pdf Quality Assurance Contract Expiration Date 07/22/2030 Installation Instructions FL17996_R4_II_ELIX0047 AVIF7N_RevB_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996_R4_AE_PER_1953_Rev4_ss.pdf Created by Independent Third Party: Yes |
|
|
| 17996.14 |
Series BFIF7N |
Series BFIF7N Non-Impact IS Fiberglass Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +38.7/-38.7 Other: |
Certification Agency Certificate FL17996_R4_C_CAC_Elixir - BFIF7N IS Door w-Side Lites (1b) ASTM June 2024 (ext.5).pdf Quality Assurance Contract Expiration Date 08/21/2029 Installation Instructions FL17996_R4_II_ELIX0040 AFIF7N-BFIF7N_RevB_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996_R4_AE_PER_1952_Rev4_ss.pdf Created by Independent Third Party: Yes |
|
|
| 17996.15 |
Series BVI63S |
Series BVI63S Non-Impact Single Inswing Door w/Fixed Lite
Insert and Outswing Storm Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +65/-65 Other: |
Certification Agency Certificate FL17996_R4_C_CAC_Elixir - BVI63S IS Door w-Storm (1a) ASTM Aug. 2023.pdf Quality Assurance Contract Expiration Date 03/24/2028 Installation Instructions FL17996_R4_II_ELIX0061 BVI63S_RevC_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996_R4_AE_PER_2244_Rev4_ss.pdf Created by Independent Third Party: Yes |
|
|
| 17996.16 |
Series BVIF7N |
Series BVIF7N Non-Impact IS Steel Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: |
Certification Agency Certificate FL17996_R4_C_CAC_Elixir - BVIF7N IS Door (1b) ASTM June 2024 (ext.5).pdf Quality Assurance Contract Expiration Date 07/29/2030 Installation Instructions FL17996_R4_II_ELIX0049 BVIF7N_BVIF7S_RevB_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996_R4_AE_PER_1953_Rev4_ss.pdf Created by Independent Third Party: Yes |
|
|
| 17996.17 |
Series BVIF7S |
Series BVIF7S Non-Impact IS Steel Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: |
Certification Agency Certificate FL17996_R4_C_CAC_Elixir - BVIF7S IS Door w-Storm (1b) ASTM June 2024 (ext.5).pdf Quality Assurance Contract Expiration Date 07/29/2030 Installation Instructions FL17996_R4_II_ELIX0049 BVIF7N_BVIF7S_RevB_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996_R4_AE_PER_1953_Rev4_ss.pdf Created by Independent Third Party: Yes |