| 17992.1 |
Capital Rib Roof Panel |
Min. 29 Ga. Capital Rib Roof Panel over 1x4 Wood Purlins over 7/16" OSB |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5psf Other: Type 1: -41.7 psf @ 24" o.c. 1x4 Wood Purlin Spacing. Fastener Pattern: 9"-9"-9"-9". Type 2: -123.5 psf @ 24" o.c. 1x4 Wood Purlin Spacing. Fastener Pattern: 6"-3"-6"-3"-6"-3"-6". Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL17992_R4_II_29 Ga. Capital Rib Roof Panel over 1x4 Wood Purlins.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL17992_R4_AE_29 Ga. Capital Rib Roof Panel over 1x4 Wood Purlins.pdf Created by Independent Third Party: Yes |
|
|
| 17992.2 |
Capital Rib Roof Panel |
Min. 29 Ga. Capital Rib Roof Panel over 7/16" OSB |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-78.5 psf Other: -22.7 psf @ 24" o.c. Fastener Pattern: 9"-9"-9"-9". -78.5 psf @ 6" o.c. Fastener Pattern: 9"-9'-9"-9". Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL17992_R4_II_29 Ga. Capital Rib Roof Panel over OSB.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL17992_R4_AE_29 Ga. Capital Rib Roof Panel over OSB.pdf Created by Independent Third Party: Yes |