FL # FL5614-R6
Application Type Revision
Code Version 2020
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Glasteel
Address/Phone/Email 425 Industrial Dr.
Moscow, TN 38057
(901) 877-3010
flvalidation@yahoo.com
 
Authorized Signature Larry Gumpert
flvalidation@yahoo.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Panel Walls
Subcategory Siding
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Zachary Priest
Florida License PE-74021
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 09/21/2033
Validated By Locke Bowden P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL5614_R6_COI_CERTIFICATE OF INDEPENDENCE-LOCKE BOWDEN, P.E..pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM D 19292016
ASTM D 28432016
ASTM D 6352014
ASTM E 15922012
ASTM G 1542012
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 12/23/2020
Date Validated 12/26/2020
Date Pending FBC Approval 01/14/2021
Date Approved 04/13/2021
 
Summary of Products
FL # Model, Number or Name Description
5614.1 Wall Panel, R Profile Light Transmitting Wall Panel 1-1/4” rib; 36” coverage
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +50.0 PSF/-50.0 PSF
 Other: +/- 50.0 psf. at 5' wall panel spans- See load table. Height limitations 75 ft. Area and separation limitations- See FBC Table 2607.4. Panels shall not be installed in the groups A-1,A-2, H, I-2,I-3. ASTM D 635 Class CC2 rating. Not for use in HVHZ Zones.
Installation Instructions
 FL5614_R6_II_FL 5614 Eval Glasteel R Profile AcrylicGC Wall Panel final SS.pdf
 Verified By: Zachary R. Priest, P.E. 74021
 Created by Independent Third Party: Yes
Evaluation Reports
 FL5614_R6_AE_FL 5614 Eval Glasteel R Profile AcrylicGC Wall Panel final SS.pdf
 Created by Independent Third Party: Yes
 