| 15076.1 |
20 Gage Galvanized Steel Storm Panels/HVHZ |
Corrugated Galvanized Steel Storm Panels retained or not by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +varies/-varies Other: Large missile impact resistant with Maximum span of 12'-4" for +/- 43.8 p.s.f. ASD Design load for regular panels (see sheet 8 & 10). Maximum span is 8'-8" for life safety panel and 5'-10" for E-Z hung panels. |
Installation Instructions FL15076_R9_II_PED Drwg. 26-070 Global Protection Prod.pdf Verified By: Walter A. Tillit Jr., P.E. PE-44167 Created by Independent Third Party: Yes Evaluation Reports FL15076_R9_AE_PER Drwg. 26-070 Global Protection Prod.pdf Created by Independent Third Party: Yes |
|
|
| 15076.2 |
24 Gage Galvanized Steel Storm Panels/NHVHZ |
Corrugated Galvanized Steel Storm Panels retained or not by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +varies/-varies Other: Large missile impact resistant with Maximum span of 12'-0" for +/- 20 psf ASD Design load and 13'-0" for +/- 20 psf ASD Design load for regular panels mounted without "h" header respectively. See sheets 3,5,9,10,11,12 & 17 of installation drawings for other spans and pressures based on mounting conditions. |
Installation Instructions FL15076_R9_II_PED Drwg. 26-069 Global Protection Prod.pdf Verified By: Walter A. Tillit Jr., P.E. PE-44167 Created by Independent Third Party: Yes Evaluation Reports FL15076_R9_AE_PER Drwg. 26-069 Global Protection Prod.pdf Created by Independent Third Party: Yes |