| 15097.1 |
a. TrustSeries Casement |
Extruded Vinyl "Non-Impact" Casement Window utilizing a Nail Fin Installation (X configuration) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 15097.1 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars |
Installation Instructions FL15097_R5_II_(b) Inst 15097.1.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15097_R5_AE_(b) Eval 15097.1.pdf Created by Independent Third Party: Yes |
|
|
| 15097.2 |
b. TrustSeries Casement |
Extruded Vinyl "Non-Impact" Casement Window (X - configuration) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 15097.2 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars |
Installation Instructions FL15097_R5_II_(b) Inst 15097.2.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15097_R5_AE_(b) Eval 15097.2.pdf Created by Independent Third Party: Yes |
|
|
| 15097.3 |
c. TrustSeries Casement |
Extruded Vinyl "Non-Impact" Casement Window utilizing a Nail Fin Installation (X configuration) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 15097.3 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars |
Installation Instructions FL15097_R5_II_(b) Inst 15097.3.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15097_R5_AE_(b) Eval 15097.3.pdf Created by Independent Third Party: Yes |
|
|
| 15097.4 |
d. Series 7100 Casement |
Extruded Vinyl "Non-Impact" Casement Window (X - configuration) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 15097.4 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars |
Installation Instructions FL15097_R5_II_(b) Inst 15097.4.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15097_R5_AE_(b) Eval 15097.4.pdf Created by Independent Third Party: Yes |
|
|
| 15097.5 |
e. Series 7100 Casement |
Extruded Vinyl "Non-Impact" Casement Window utilizing a Nail Fin Installation (X configuration) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 15097.5 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars |
Installation Instructions FL15097_R5_II_(b) Inst 15097.5.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL15097_R5_AE_(b) Eval 15097.5.pdf Created by Independent Third Party: Yes |