| 38840.1 |
01 | 26ga IM36TR on purlins |
Structural 26ga (min) IM36TR exposed fastener ag panel on 16ga (min) purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-110 Other: -110psf with (1) fastener per rib @ 24" o.c. | -45.5psf with (1) fastener per rib @ 60" o.c. |
Installation Instructions FL38840_R2_II_26ga_IM36TR_purlins.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL38840_R2_AE_26ga_IM36TR_purlins.pdf Created by Independent Third Party: Yes |
|
|
| 38840.2 |
02 | 26ga IM36PBR on purlins |
Structural 26ga (min) IM36PBR exposed fastener PBR panel on 16ga (min) purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-105 Other: -105psf with (1) fastener per rib @ 24" o.c. | -45.5psf with (1) fastener per rib @ 60" o.c. |
Installation Instructions FL38840_R2_II_26ga_IM36PBR_purlins.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL38840_R2_AE_26ga_IM36PBR_purlins.pdf Created by Independent Third Party: Yes |