| 46943.1 |
Mosaic Grand Shingle |
26ga stone coated steel panels over 15/32" plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-183.5 Other: The design pressure (DP) noted in this application pertains to one tested assembly, with a factor of safety of 2.0 applied. Refer to Table 1 of the attached test report for all assemblies, fastening details and DPs. |
Installation Instructions FL46943_R0_II_Mosaic ALL Installation Manual 2024.pdf Verified By: Francis Joseph Rotonda 75135 Test Reports FL46943_R0_TR_2024_04_02_PRI_2581T0008, TAS 100, Mosaic Grand Shingle, with Battens.pdf FL46943_R0_TR_2024_04_02_PRI_2581T0012, TAS 125 UL 580 1897, Mosaic Grand Shingle.pdf FL46943_R0_TR_2024_04_04_PRI_2581T0005_ASTM E108, Class A_Mosaic Grand Shingle.pdf |
|
|
| 46943.2 |
Mosaic Shakewood |
26ga stone coated steel panels over 15/32" plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-183.5 Other: The design pressure (DP) noted in this application pertains to one tested assembly, with a factor of safety of 2.0 applied. Refer to Table 1 of the attached test report for all assemblies, fastening details and DPs. |
Installation Instructions FL46943_R0_II_Mosaic ALL Installation Manual 2024.pdf Verified By: Francis Joseph Rotonda 75135 Test Reports FL46943_R0_TR_2024_04_02_PRI_2581T0008, TAS 100, Mosaic Grand Shingle, with Battens.pdf FL46943_R0_TR_2024_04_02_PRI_2581T0012, TAS 125 UL 580 1897, Mosaic Grand Shingle.pdf FL46943_R0_TR_2024_04_04_PRI_2581T0005_ASTM E108, Class A_Mosaic Grand Shingle.pdf |
|
|
| 46943.3 |
Mosaic Shakewood PV & Mosaic Powerhause ISRS Panel |
26ga steel panels over 15/32" plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-183.5 Other: The design pressure (DP) noted in this application pertains to one tested assembly, with a factor of safety of 2.0 applied. Refer to Table 1 of the attached test report for all assemblies, fastening details and DPs. Listing does not include evaluation of building integrated photovoltaic (BIPV) components. |
Installation Instructions FL46943_R0_II_Mosaic_Powerhause_ISRS_Installation Guide.pdf Verified By: Francis Joseph Rotonda 75135 Test Reports FL46943_R0_TR_2024_04_02_PRI_2581T0008, TAS 100, Mosaic Grand Shingle, with Battens.pdf FL46943_R0_TR_2024_04_02_PRI_2581T0012, TAS 125 UL 580 1897, Mosaic Grand Shingle.pdf FL46943_R0_TR_2024_04_04_PRI_2581T0005_ASTM E108, Class A_Mosaic Grand Shingle.pdf |
|
|
| 46943.4 |
Mosaic Sicily Tile |
26ga. stone coated steel panels over 15/32" plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-161 Other: The design pressure (DP) noted in this application pertains to one tested assembly, with a factor of safety of 2.0 applied. Refer to Table 1 of the attached test report for all assemblies, fastening details and DPs. |
Installation Instructions FL46943_R0_II_Mosaic ALL Installation Manual 2024.pdf Verified By: Francis Joseph Rotonda 75135 Test Reports FL46943_R0_TR_2581T0004- Report - ASTM E108 Class A Mosaic Sicily Tile.pdf FL46943_R0_TR_2581T0006 Report - TAS 100 for Mosaic Sicily Battens.pdf FL46943_R0_TR_2581T0009 - Report - TAS 125 UL 580 1897 Mosaic Sicily Tile 1532 plywood (1).pdf |