Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL46926-R1
Application Type Revision
Code Version 2026
Application Status Applied For
 
Comments 1st validation- 10/13/26. was set to re-apply on 10/19/26. m.c.
Archived
 
Product Manufacturer CENTRIA
Address/Phone/Email 700 State Highway 121 Bypass
Suite 200
Lewisville, TX 75067
(972) 221-6656
ruben.herrera@nucor.com
 
Authorized Signature Chris Scoville
fpa@qualtim.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Structural Components
Subcategory Structural Wall
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Ryan J Dexter
Florida License PE-69484
Quality Assurance Entity Farabaugh Engineering and Testing, LLC
Quality Assurance Contract Expiration Date 12/31/2030
Validated By Justin M Lanier, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL46926_R1_COI_261019_ENG-2607-329_FPA_Versawall Hplus_FINAL Sealed.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E283/E283-M2019
ASTM E3312023
ASTM E842024
FM 48802017
NFPA 2592023
NFPA 2862024
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 10/02/2026
Date Validated
 
Summary of Products
FL # Model, Number or Name Description
46926.1 Versawall H+ Panels Versawall H+ Insulated Metal Panels provide a sleek, modern aesthetic, and energy-efficient wall where horizontal applications are desired.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: N/A
 Other: See Installation Instructions for design wind pressure Tables for various conditions.
Installation Instructions
 FL46926_R1_II_261019_ENG-2607-329_FPA_Versawall Hplus_FINAL Sealed.pdf
 Verified By: DrJ Engineering, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL46926_R1_AE_261019_ENG-2607-329_FPA_Versawall Hplus_FINAL Sealed.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex