| 13468.1 |
QTB(X) Blue |
The QTB(X) provides a continuous load path from the top of the wall to the foundation. Consists of a wire rope with threaded studs swaged to each end. 3/16" diameter, 7x19, galvanized steel wire with a minimum nominal strength of 4,200 lbs |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Certification Agency Certificate FL13468_R11_C_CAC_250113_FL13468_0910-01_CAC.pdf Quality Assurance Contract Expiration Date 04/01/2027 Installation Instructions FL13468_R11_II_230815_QTB_QTG_QTO_QTR_Install_Instructions.pdf Verified By: DrJ Engineering LLC Created by Independent Third Party: Evaluation Reports FL13468_R11_AE_250110_TER0910-01_SEALED.pdf Created by Independent Third Party: Yes |
|
|
| 13468.2 |
QTG(X) Green |
The QTG(X) provides a continuous load path from the top of the wall to the foundation. Consists of a wire rope with threaded studs swaged to each end. 1/4" diameter, 7x19, galvanized steel wire with a minimum nominal strength of 7,000 lbs. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Certification Agency Certificate FL13468_R11_C_CAC_250113_FL13468_0910-01_CAC.pdf Quality Assurance Contract Expiration Date 04/01/2027 Installation Instructions FL13468_R11_II_230815_QTB_QTG_QTO_QTR_Install_Instructions.pdf Verified By: DrJ Engineering LLC Created by Independent Third Party: Evaluation Reports FL13468_R11_AE_250110_TER0910-01_SEALED.pdf Created by Independent Third Party: Yes |
|
|
| 13468.3 |
QTO(X) Orange |
The QTO(X) provides a continuous load path from the top of the wall to the foundation. Consists of a wire rope with threaded studs swaged to each end. 5/16" diameter, 7x19, galvanized steel wire with a minimum nominal strength of 9,800 lbs |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Certification Agency Certificate FL13468_R11_C_CAC_250113_FL13468_0910-01_CAC.pdf Quality Assurance Contract Expiration Date 04/01/2027 Installation Instructions FL13468_R11_II_230815_QTB_QTG_QTO_QTR_Install_Instructions.pdf Verified By: DrJ Engineering LLC Created by Independent Third Party: Evaluation Reports FL13468_R11_AE_250110_TER0910-01_SEALED.pdf Created by Independent Third Party: Yes |
|
|
| 13468.4 |
QTR(X) Red |
The QTR(X) provides a continuous load path from the top of the wall to the foundation. Consists of a wire rope with threaded studs swaged to each end. 3/8" diameter, 7x19, galvanized steel wire with a minimum nominal strength of 14,400 lbs. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Certification Agency Certificate FL13468_R11_C_CAC_250113_FL13468_0910-01_CAC.pdf Quality Assurance Contract Expiration Date 04/01/2027 Installation Instructions FL13468_R11_II_230815_QTB_QTG_QTO_QTR_Install_Instructions.pdf Verified By: DrJ Engineering LLC Created by Independent Third Party: Evaluation Reports FL13468_R11_AE_250110_TER0910-01_SEALED.pdf Created by Independent Third Party: Yes |
|
|
| 13468.5 |
QuickTie Adhesives |
QE-1 Epoxy Adhesive and QE-2 Epoxy Adhesive |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Certification Agency Certificate FL13468_R11_C_CAC_250113_FL13468_0910-01_CAC.pdf Quality Assurance Contract Expiration Date 04/01/2027 Installation Instructions FL13468_R11_II_FL_13468.5_QuickTie_Adhesives_Install.pdf Verified By: DrJ Engineering LLC Created by Independent Third Party: Evaluation Reports FL13468_R11_AE_250110_TER0910-01_SEALED.pdf Created by Independent Third Party: Yes |