| 13446.1 |
Master Seam |
Master Seam over 1/2" plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +na/-76 Other: The required wind load for design shall be determined in accordance with the FBC, Sect 1609. The max clip/fastener spacing shown on installation instructions should not be exceeded. Any rational analysis computations shall be prepared by a qualified design professional and in compliance with FBC. Product is for use outside the HVHZ. Min roof pitch 0.25/12. Minimum 1” length screw required for full penetration through wood deck. Design pressure shown is for comparison to factored pressures. |
Installation Instructions FL13446_R6_II_Master Seam Installation.pdf Verified By: Nanette Dean FL45851 Test Reports FL13446_R6_TR_HTL to ATI letter.pdf FL13446_R6_TR_TestReport.pdf |
|
|
| 13446.2 |
Rib-12 |
Rib-12 panel over 1/2" plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +na/-69 Other: The required wind load for design shall be determined in accordance with FBC, Sec 1609. The maximum fastener spacing shown on installation instructions should not be exceeded. Any rational analysis computations shall be prepared by a qualified design professional and in compliance with the FBC. Product is for use outside the HVHZ. Minimum roof pitch: 0.5/12. Minimum 1” length screw required for full penetration through wood deck. Design pressure shown is for comparison to factored pressures. |
Installation Instructions FL13446_R6_II_Rib-12 Installation.pdf Verified By: Nanette Dean FL45851 Test Reports FL13446_R6_TR_HTL to ATI letter.pdf FL13446_R6_TR_TestReport.pdf |
|
|
| 13446.3 |
Rib-6 |
Rib-6 panel over 1/2" plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +na/-84 Other: The required wind load for design shall be determined in accordance with FBC, Sec 1609. The maximum fastener spacing shown on installation instructions should not be exceeded. Any rational analysis computations shall be prepared by a qualified design professional and in compliance with the FBC. Product is for use outside the HVHZ. Minimum roof pitch 0.5:12. Minimum 1” length screw required for full penetration through wood deck. Design pressure shown is for comparison to factored pressures. |
Installation Instructions FL13446_R6_II_Rib-6 Installation.pdf Verified By: Nanette Dean FL45851 Test Reports FL13446_R6_TR_HTL to ATI letter.pdf FL13446_R6_TR_TestReport.pdf |