Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL6267-R19
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany, NJ 07054
(800) 766-3411
mstieh@gaf.com
 
Authorized Signature Michael Stieh
michael.stieh@gaf.com
 
Technical Representative William Broussard
Address/Phone/Email 1 Campus Drive
Parsippany, NJ 07054
(800) 766-3411
TechnicalQuestionsGAF@gaf.com
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Roofing Accessories that are an Integral Part of the Roofing System
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Robert Nieminen
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/13/2028
Validated By John W. Knezevich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL6267_R19_COI_2023_07_COI_NIEMINEN.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM D19292016
ASTM D6352014
ASTM E3302014
ASTM G1552013
TAS 100(A)2023
TAS 114, Appendix E2011
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 04/26/2024
Date Validated 04/30/2024
Date Pending FBC Approval 05/04/2024
Date Approved 06/18/2024
Date Revised 10/21/2025
 
Summary of Products
FL # Model, Number or Name Description
6267.1 GAF Attic Ventilation Products (NON-HVHZ) Low profile roof ventilation products for use in FBC non-HVHZ jurisdictions.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-215
 Other: 1.) The noted design pressures applies to one particular vent installation. Refer to PEER Section 5.6. 2.) Refer to PEER Section 5 for Limits of Use.
Installation Instructions
 FL6267_R19_II_2024_04_25_FINAL_PEER-GAF-001.A_VENTS_FL6267-R19.pdf
 Verified By: Robert Nieminen PE-59166
 Created by Independent Third Party: Yes
Evaluation Reports
 FL6267_R19_AE_2024_04_25_FINAL_PEER-GAF-001.A_VENTS_FL6267-R19.pdf
 Created by Independent Third Party: Yes
 