Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL47223
Application Type New
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer WINCO
Address/Phone/Email 6200 Maple Avenue
St Louis, MO 63130
(314) 725-8088   Ext 285
andrewkearney@wincowindow.com
 
Authorized Signature Andrew Kearney
andrewkearney@wincowindow.com
 
Technical Representative Andrew Kearney
Address/Phone/Email 6200 Maple Ave
St. Louis, MO 63130
(314) 725-8088   Ext 285
andrewkearney@wincowindow.com
 
Quality Assurance Representative Marcus Thomas
Address/Phone/Email 6200 Maple Ave
St. Louis, MO 63130
(314) 725-8088   Ext 234
MarcusThomas@wincowindow.com
 
Category Windows
Subcategory Fixed
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Wayne K Helmila
Florida License PE-59092
Quality Assurance Entity Fenestration and Glazing Industry Alliance (formerly AAMA)
Quality Assurance Contract Expiration Date 05/17/2029
Validated By Scott Wolters, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL47223_R0_COI_WKH-1150 FX-FX-w HI Sash-Stmpd Eval Report 12-08-24.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA 4502020
AAMA 501.82014
AAMA 5062016
AAMA/WDMA/CSA 101/I.S.2/A4402017
ASTM E13002016
ASTM E18862019
ASTM E19962020
ASTM E3302021
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 12/20/2024
Date Validated 01/08/2025
Date Pending FBC Approval 01/08/2025
Date Approved 02/11/2025
 
Summary of Products
FL # Model, Number or Name Description
47223.1 1150 / 8800 Retrofit 1150 Fixed E-Missile w/ 8800 Retrofit - Human Impact Blind Sash on the Interior
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +80/-80
 Other: Interior Human Impact Blind Sash Rated for 2,000 ft-lb human impact per AAMA 501.8
Installation Instructions
 FL47223_R0_II_WKH - 1150 FX-FX-w HI Sash-Stamped Dwgs 01-08-25.pdf
 Verified By: Wayne K. Helmila 59092
 Created by Independent Third Party: Yes
Evaluation Reports
 FL47223_R0_AE_WKH-1150 FX-FX-w HI Sash-Stmpd Eval Report 12-08-24.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 