| 48283.1 |
a. 9400 Series |
Extruded PVC Single Hung Window (New Construction) with "Non-Impact" Insulated Glass - Nail Fin Application |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 48283.1 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. |
Installation Instructions FL48283_R1_II_(e) Inst 48283.1.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL48283_R1_AE_(e) Eval 48283.1.pdf Created by Independent Third Party: Yes |
|
|
| 48283.2 |
b. 9400 Series |
Extruded PVC Single Hung Window (Replacement) with "Non-Impact" Insulated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 48283.2 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. |
Installation Instructions FL48283_R1_II_(e) Inst 48283.2.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL48283_R1_AE_(e) Eval 48283.2.pdf Created by Independent Third Party: Yes |
|
|
| 48283.3 |
c. 9400 Series |
Extruded PVC Single Hung Window (New Construction) with "Non-Impact" Insulated Glass - Nail Fin Application |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 48283.3 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. |
Installation Instructions FL48283_R1_II_(e) Inst 48283.3.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL48283_R1_AE_(e) Eval 48283.3.pdf Created by Independent Third Party: Yes |
|
|
| 48283.4 |
d. 9400 Series |
Extruded PVC Single Hung Window (Replacement) with "Non-Impact" Insulated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 48283.4 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. |
Installation Instructions FL48283_R1_II_(e) Inst 48283.4.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL48283_R1_AE_(e) Eval 48283.4.pdf Created by Independent Third Party: Yes |
|
|
| 48283.5 |
e. 9700 Series |
Extruded PVC Single Hung Window (New Construction) with "Non-Impact" Insulated Glass - Nail Fin Application |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 48283.5 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. |
Installation Instructions FL48283_R1_II_(e) Inst 48283.5.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL48283_R1_AE_(e) Eval 48283.5.pdf Created by Independent Third Party: Yes |
|
|
| 48283.6 |
f. 9700 Series |
Extruded PVC Single Hung Window (Replacement) with "Non-Impact" Insulated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 48283.6 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. |
Installation Instructions FL48283_R1_II_(e) Inst 48283.6.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL48283_R1_AE_(e) Eval 48283.6.pdf Created by Independent Third Party: Yes |
|
|
| 48283.7 |
g. 9800 Series Vinyl Single Hung Window |
Extruded PVC Single Hung Window (New Construction) with "Impact" Insulated Glass - Nail Fin Application |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 48283.7 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. |
Installation Instructions FL48283_R1_II_(e) Inst 48283.7.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL48283_R1_AE_(e) Eval 48283.7.pdf Created by Independent Third Party: Yes |
|
|
| 48283.8 |
h. 9800 Series Vinyl Single Hung Window |
Extruded PVC Single Hung Window (New Construction) with "Impact" Insulated Glass - Nail Fin Application |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 48283.8 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. |
Installation Instructions FL48283_R1_II_(e) Inst 48283.8.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL48283_R1_AE_(e) Eval 48283.8.pdf Created by Independent Third Party: Yes |
|
|
| 48283.9 |
i. 9800 Series Vinyl Single Hung Window |
Extruded PVC Single Hung Window (Replacement) with "Impact" Insulated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 48283.9 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. |
Installation Instructions FL48283_R1_II_(e) Inst 48283.9.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL48283_R1_AE_(e) Eval 48283.9.pdf Created by Independent Third Party: Yes |
|
|
| 48283.10 |
j. 9800 Series Vinyl Single Hung Window |
Extruded PVC Single Hung Window (Replacement) with "Impact" Insulated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 48283.10 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. |
Installation Instructions FL48283_R1_II_(e) Inst 48283.10.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL48283_R1_AE_(e) Eval 48283.10.pdf Created by Independent Third Party: Yes |