| 48272.1 |
Metalite 8000 ACM Panel System |
4mm ACM Panel, 48" (max) x 120", on 14 Ga. steel hat channels over 2x6 wood studs and 5/8" plywood sheathing (min). |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +80/-80 Other: This is a rainscreen system and may only be installed over a weather resistive barrier meeting the requirements of FBC Section 1404.2. |
Installation Instructions FL48272_R0_II_M8000-MD-4Ft-Wood 5-1-26.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX Test Reports FL48272_R0_TR_t1273.01-801-18-r0.pdf |
|
|
| 48272.2 |
Metalite 8000 ACM Panel System |
4mm ACM Panel, 24" (max) x 120", on 16 Ga. steel hat channels over 2x4 wood studs and 5/8" plywood sheathing (min). |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +120/-120 Other: This is a rainscreen system and may only be installed over a weather-resistive barrier meeting the requirements of FBC Section 1404.2. |
Installation Instructions FL48272_R0_II_M8000-MD-2Ft-Wood 5-1-26.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX Test Reports FL48272_R0_TR_t1273.01-801-18-r0.pdf |
|
|
| 48272.3 |
Metalite 8000 ACM Panel System |
4mm ACM Panel, 48" (max) x 120", on 14 Ga. steel hat channels over 18 Ga. metal studs and 5/8" plywood sheathing (min). |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +80/-80 Other: This is a rainscreen system and may only be installed over a weather-resistive barrier meeting the requirements of FBC Section 1404.2. |
Installation Instructions FL48272_R0_II_M8000-MD-4Ft-Metal 5-1-26.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX Test Reports FL48272_R0_TR_t1273.01-801-18-r0.pdf |
|
|
| 48272.4 |
Metalite 8000 ACM Panel System |
4mm ACM Panel, 24" (max) x 120", on 16 Ga. steel hat channels over 18 Ga. steel studs and 5/8" plywood sheathing (min). |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +120/-120 Other: This is a rainscreen system and may only be installed over a weather-resistive barrier meeting the requirements of FBC Section 1404.2. |
Installation Instructions FL48272_R0_II_M8000-MD-2Ft-Metal 5-1-26.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX Test Reports FL48272_R0_TR_t1273.01-801-18-r0.pdf |