| 48272.1 |
Metalite 8000 ACM Panel System |
4mm ACM Panel, 48" (max) x 120", on 14 Ga. steel hat channels over 2x6 wood studs and 5/8" plywood sheathing (min)., 18 Ga. metal studs and 5/8" plywood sheathing (min.), OR CMU/concrete wall |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +80/-80 Other: This is a rainscreen system and may only be installed over a weather resistive barrier meeting the requirements of FBC Section 1404.2. |
Installation Instructions FL48272_R1_II_Metalite®8000 installation manual - Rev1.1 1.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL48272_R1_AE_NOA 26-0603.03 Metalite 8000 Listing.pdf |
|
|
| 48272.2 |
Metalite 8000 ACM Panel System |
4mm ACM Panel, 24" (max) x 120", on 16 Ga. steel hat channels over 2x6 wood studs and 5/8" plywood sheathing (min)., 18 Ga. metal studs and 5/8" plywood sheathing (min.), OR CMU/concrete wall |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +120/-120 Other: This is a rainscreen system and may only be installed over a weather-resistive barrier meeting the requirements of FBC Section 1404.2. |
Installation Instructions FL48272_R1_II_Metalite®8000 installation manual - Rev1.1 1.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL48272_R1_AE_NOA 26-0603.03 Metalite 8000 Listing.pdf |