| 12098.1 |
NichiBoard Plank |
Lap siding boards in widths from 5-1/4" up to 12"; all boards are 12 feet in length and 5/16" in thickness.
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +85/-85 Other: Installation must be in accordance with CCRR-0258. Maximum pressure of HVHZ assembly detail shown. See evaluation report for various assembly details and design pressures. |
Installation Instructions FL12098_R10_II_2023-08-15 CCRR-0258.pdf Verified By: Christopher Bowness, P.E. 64748 Created by Independent Third Party: Yes Evaluation Reports FL12098_R10_AE_2023-08-15 CCRR-0258.pdf |
|
|
| 12098.2 |
NichiPanel |
Panels are available in 4-foot widths and 3 lengths: 8', 10', and 12'. All panels are 5/16" thick. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +75/-75 Other: Installation must be in accordance with CCRR-0258. Maximum pressure of HVHZ assembly detail shown. See evaluation report for various assembly details and design pressures. |
Installation Instructions FL12098_R10_II_2023-08-15 CCRR-0258.pdf Verified By: Christopher Bowness, P.E. 64748 Created by Independent Third Party: Yes Evaluation Reports FL12098_R10_AE_2023-08-15 CCRR-0258.pdf |
|
|
| 12098.3 |
NichiShake |
Primed cedar shake panels available in widths from 6-/14" up to 12"; all boards are 18" in height.
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +31/-31 Other: Maximum pressure of non-HVHZ assembly detail shown. See evaluation report for assembly details and design pressures. |
Installation Instructions FL12098_R10_II_2023-08-15 CCRR-0258.pdf Verified By: Christopher Bowness, P.E. 64748 Created by Independent Third Party: Yes Evaluation Reports FL12098_R10_AE_2023-08-15 CCRR-0258.pdf |
|
|
| 12098.4 |
NichiSoffit |
12",16" wide by 12' long, or 24", 48" wide by 8 feet long soffits. Product is 1/4" thick. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +70/-70 Other: Installation must be in accordance with CCRR-0258. Maximum pressure of HVHZ assembly detail shown. See evaluation report for various assembly details and design pressures. |
Installation Instructions FL12098_R10_II_2023-08-15 CCRR-0258.pdf Verified By: Christopher Bowness, P.E. 64748 Created by Independent Third Party: Yes Evaluation Reports FL12098_R10_AE_2023-08-15 CCRR-0258.pdf |
|
|
| 12098.5 |
NichiStaggered / NichiStraight |
16" wide by 4' long panels designed to look like individual cedar shake. The panels are 5/16" thick. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: Installation must be in accordance with CCRR-0258. Maximum pressure of HVHZ assembly detail shown. See evaluation report for various assembly details and design pressures. |
Installation Instructions FL12098_R10_II_2023-08-15 CCRR-0258.pdf Verified By: Christopher Bowness, P.E. 64748 Created by Independent Third Party: Yes Evaluation Reports FL12098_R10_AE_2023-08-15 CCRR-0258.pdf |