| 16369.1 |
1630 SS IR |
1630 SS IR Zone 4 LMI SMI Curtain Wall System |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Curtain wall size, pressure, assembly and installation requirements are to be as specified in the attached drawing. Job required design wind pressure shall be calculated in accordance with the Florida Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This curtain wall system is rated as a wind zone 4 missile level "A", āDā, and "E" product. All glass meets the requirements of the current ASTM E1300 Standard. |
Installation Instructions FL16369_R7_II_KAW009 SS 2026-02-12.pdf Verified By: Hermes F. Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL16369_R7_AE_PER10450 SS 2026-02-12.pdf Created by Independent Third Party: Yes |
|
|
| 16369.2 |
7 13/16" Deep 1630 SS IR |
7 13/16" Deep 1630 SS IR Zone 3 LMI Curtain wall system |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: Curtain wall size, pressure, assembly and installation requirements are to be as specified in the attached drawing. Job required design wind pressure shall be calculated in accordance with the Florida Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This curtain wall system is rated as a wind zone 3 missile level āDā product. |
Installation Instructions FL16369_R7_II_KAW008 SS 2023-10-19.pdf Verified By: Hermes F. Norero, P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL16369_R7_AE_PER8882 SS 2023-10-19.pdf Created by Independent Third Party: Yes |