| 22840.1 |
0.024" Aluminum |
3" Riser Roof Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +48.6/-48.6 Other: Design Pressure varies with span. Please see installation instructions |
Installation Instructions FL22840_R3_II_Alumflo - Riser Roof Panel (Aluminum and Galvalume) SHEET A-1.1.pdf FL22840_R3_II_Alumflo - Riser Roof Panel (Aluminum and Galvalume) SHEET A-1.2.pdf FL22840_R3_II_Alumflo - Riser Roof Panel (Aluminum and Galvalume) SHEET A-1.3.pdf Verified By: Frederic P. Carrie 60791 Created by Independent Third Party: Yes Evaluation Reports FL22840_R3_AE_FCPE Consultants Report 062117.2 (2).pdf Created by Independent Third Party: Yes |
|
|
| 22840.2 |
0.030" Aluminum |
3" Riser Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +48.6/-48.6 Other: Design Pressure varies with span. Please see installation instructions |
Installation Instructions FL22840_R3_II_Alumflo - Riser Roof Panel (Aluminum and Galvalume) SHEET A-1.1.pdf FL22840_R3_II_Alumflo - Riser Roof Panel (Aluminum and Galvalume) SHEET A-1.2.pdf FL22840_R3_II_Alumflo - Riser Roof Panel (Aluminum and Galvalume) SHEET A-1.3.pdf Verified By: Frederic P. Carrie PE PE #60791 Created by Independent Third Party: Yes Evaluation Reports FL22840_R3_AE_FCPE Consultants Report 062117.2 (2).pdf Created by Independent Third Party: Yes |
|
|
| 22840.3 |
24 Gage Galvalume |
3" Riser Roof Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +48.6/-48.6 Other: Design Pressure varies with span. Please see installation instructions |
Installation Instructions FL22840_R3_II_Alumflo - Riser Roof Panel (Aluminum and Galvalume) SHEET S-1.1 (1).pdf FL22840_R3_II_Alumflo - Riser Roof Panel (Aluminum and Galvalume) SHEET S-1.2.pdf FL22840_R3_II_Alumflo - Riser Roof Panel (Aluminum and Galvalume) SHEET S-1.3.pdf Verified By: Frederic P. Carrie PE #60791 Created by Independent Third Party: Yes Evaluation Reports FL22840_R3_AE_FCPE Consultants Report 062117.2 (2).pdf Created by Independent Third Party: Yes |
|
|
| 22840.4 |
26 Gage Galvalume |
3" Riser Roof Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +48.6/-48.6 Other: Design Pressure varies with span. Please see installation instructions |
Installation Instructions FL22840_R3_II_Alumflo - Riser Roof Panel (Aluminum and Galvalume) SHEET S-1.1 (1).pdf FL22840_R3_II_Alumflo - Riser Roof Panel (Aluminum and Galvalume) SHEET S-1.2.pdf FL22840_R3_II_Alumflo - Riser Roof Panel (Aluminum and Galvalume) SHEET S-1.3.pdf Verified By: Frederic P. Carrie PE PE #66356 Created by Independent Third Party: Yes Evaluation Reports FL22840_R3_AE_FCPE Consultants Report 062117.2 (2).pdf Created by Independent Third Party: Yes |