27460.1 |
1 - "Knotwood" Series KED150 (R4) |
0.080” Aluminum interlocking wall panel system with a wood-grain texture appearance, attached through optional Sheathing into wood supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +120/-120 Other: Install in compliance with the installation method listed in this report and applicable code sections of FBC 6th Edition (2017). See Report for Limitations and Conditions of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment. |
Installation Instructions FL27460_R4_II_01_Knotwood_KED_R4_EVALREPORT.pdf Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL27460_R4_AE_01_Knotwood_KED_R4_EVALREPORT.pdf Created by Independent Third Party: Yes |
|
27460.2 |
2 - "Knotwood" Series KED150 (R4) |
0.080” Aluminum interlocking wall panel system with a wood-grain texture appearance, attached through 1/2" gypsum board into wood supports |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +120/-120 Other: Install in compliance with the installation method listed in this report and applicable code sections of FBC 6th Edition (2017). See Report for Limitations and Conditions of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment. |
Installation Instructions FL27460_R4_II_02_Knotwood_KED_HVHZ_R4_EVALREPORT.pdf Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL27460_R4_AE_02_Knotwood_KED_HVHZ_R4_EVALREPORT.pdf Created by Independent Third Party: Yes |
|
27460.3 |
3 - "Knotwood" Series KEC150 (R4) |
0.055” Aluminum interlocking wall panel system with a wood-grain texture appearance, attached through 5/8" plywood sheathing into wood supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +120/-120 Other: Install in compliance with the installation method listed in this report and applicable code sections of FBC 6th Edition (2017). See Report for Limitations and Conditions of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment. |
Installation Instructions FL27460_R4_II_03_Knotwood_KEC_nR4_EVALREPORT.pdf Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL27460_R4_AE_03_Knotwood_KEC_nR4_EVALREPORT.pdf Created by Independent Third Party: Yes |
|
27460.4 |
4 - "Knotwood" Series KEC150 (R4) |
0.055” Aluminum interlocking wall panel system with a wood-grain texture appearance, attached through 5/8" plywood sheathing into wood supports |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +120/-120 Other: Install in compliance with the installation method listed in this report and applicable code sections of FBC 6th Edition (2017). See Report for Limitations and Conditions of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment. |
Installation Instructions FL27460_R4_II_04_Knotwood_KEC_nR4_HVHZ_EVALREPORT.pdf Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL27460_R4_AE_04_Knotwood_KEC_nR4_HVHZ_EVALREPORT.pdf Created by Independent Third Party: Yes |