| 27499.1 |
DM Class 1000 1" Nailstrip |
26 Ga. galvalume coated steel roof panel, 16" wide, with 1" snap fit seams. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. |
Installation Instructions FL27499_R4_II_4991 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_4991 Eval.pdf Created by Independent Third Party: Yes |
|
|
| 27499.2 |
DM Class 1000 1" Nailstrip, |
.032" Aluminum roof panel, 16" wide, with 1" snap fit seams. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. |
Installation Instructions FL27499_R4_II_4992 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_4992 Eval.pdf Created by Independent Third Party: Yes |
|
|
| 27499.3 |
DM Class 1050 1 1/2" Nailstrip |
.032" Aluminum Roof Panel, 19" Wide, with 1 1/2" snap fit seams. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. |
Installation Instructions FL27499_R4_II_4993 Dwg.pdf Verified By: Scott Wolters, P.E. FLPE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_4993 Eval.pdf Created by Independent Third Party: Yes |
|
|
| 27499.4 |
DM Class 1050 1 1/2" Nailstrip |
24 Ga. Galvalume coated steel roof panel, 19" wide, with 1 1/2" snap fit seams |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. |
Installation Instructions FL27499_R4_II_4994 Dwg.pdf Verified By: Scott Wolters, P.E. FLPE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_4994 Eval.pdf Created by Independent Third Party: Yes |
|
|
| 27499.5 |
DM Class 1150 1" Mechanical Seam |
.032" Aluminum roof panel, 21" wide, with 1" standing seams. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval Report for Limits of Use. |
Installation Instructions FL27499_R4_II_4995 Dwg.pdf Verified By: Scott Wolters FLPE# 62394 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_4995 Eval.pdf Created by Independent Third Party: Yes |
|
|
| 27499.6 |
DM Class 1150 1" Mechanical Seam |
.032" Aluminum roof panel, 21" wide, with 1" standing seams. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Installation Drawings and Eval Report for Limits of Use. |
Installation Instructions FL27499_R4_II_4996 Dwg.pdf Verified By: Scott Wolters FLPE# 62394 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_4996 Eval.pdf Created by Independent Third Party: Yes |
|
|
| 27499.7 |
DM Class 1150 1" Mechanical Seam |
26 Ga. Galvalume coated steel roof panel, 21" wide, with 1" standing seams. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Installation Drawings and Eval Report for Limits of Use. |
Installation Instructions FL27499_R4_II_4997 Dwg.pdf Verified By: Scott Wolters FLPE# 62394 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_4997 Eval.pdf Created by Independent Third Party: Yes |
|
|
| 27499.8 |
DM Class 1500 1 1/2" Mechanical Seam |
.032" Aluminum roof panel, 20" wide, with 1 1/2" standing seams. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. |
Installation Instructions FL27499_R4_II_4998 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_4998 Eval.pdf Created by Independent Third Party: Yes |
|
|
| 27499.9 |
DM Class 1500 1 1/2" Mechanical Seam |
16 oz. Copper roof panel, 16" wide, with 1 1/2" standing seams. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. |
Installation Instructions FL27499_R4_II_4999 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_4999 Eval.pdf Created by Independent Third Party: Yes |
|
|
| 27499.10 |
DM Class 1500 1 1/2" Mechanical Seam |
26 Ga. galvalume coated steel roof panel, 16" wide, with 1 1/2" standing seams. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. |
Installation Instructions FL27499_R4_II_49910 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_49910 Eval.pdf Created by Independent Third Party: Yes |
|
|
| 27499.11 |
DM Class 1500 1 1/2" Mechanical Seam |
.032" Aluminum roof panel, 16" wide, with 1 1/2" standing seams. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. |
Installation Instructions FL27499_R4_II_49911 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_49911 Eval.pdf Created by Independent Third Party: Yes |
|
|
| 27499.12 |
DM Class 1500 1 1/2" Mechanical Seam |
24 Ga. galvalume coated steel roof panel, 16" wide, with 1 1/2" standing seams. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. |
Installation Instructions FL27499_R4_II_49912 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_49912 Eval.pdf Created by Independent Third Party: Yes |
|
|
| 27499.13 |
DM Class 1500 1 1/2" Mechanical Seam, |
24 Ga. galvalume coated steel roof panel, 20" wide, with 1 1/2" standing seams. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. |
Installation Instructions FL27499_R4_II_49913 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_49913 Eval.pdf Created by Independent Third Party: Yes |
|
|
| 27499.14 |
DM Class 1750 1 3/4" Snaplock |
24 Ga. Galvalume coated steel roof panel, 18" wide, with 1 3/4" Snaplock seams, attached to metal deck. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. |
Installation Instructions FL27499_R4_II_49914 Dwg.pdf Verified By: Scott Wolters, P.E. FLPE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_49914 Eval.pdf Created by Independent Third Party: Yes |
|
|
| 27499.15 |
DM Class 1750 1 3/4" Snaplock |
.032" Aluminum roof panel, 18" wide, with 1 3/4" Snaplock seams, attached to metal deck. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. |
Installation Instructions FL27499_R4_II_49915 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_49915 Eval.pdf Created by Independent Third Party: Yes |
|
|
| 27499.16 |
DM Class 1750 1 3/4" Snaplock |
.032" aluminum roof panel, 18" wide, with 1 3/4" Snaplock seams. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. |
Installation Instructions FL27499_R4_II_49916 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_49916 Eval.pdf Created by Independent Third Party: Yes |
|
|
| 27499.17 |
DM Class 1750 1 3/4" Snaplock |
24 Ga. galvalume coated steel roof panel, 18" wide, with 1 3/4" Snaplock seams. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. |
Installation Instructions FL27499_R4_II_49917 dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_49917 Eval.pdf Created by Independent Third Party: Yes |
|
|
| 27499.18 |
DM Class 2000 2" Mechanical Seam |
.032 Aluminum roof panel, 18" wide, with 2" standing seams. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. |
Installation Instructions FL27499_R4_II_49918 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_49918 Eval.pdf Created by Independent Third Party: Yes |
|
|
| 27499.19 |
DM Class 2000 2" Mechanical Seam |
24 Ga. galvalume coated steel roof panel, 18" wide, with 2" standing seams. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. |
Installation Instructions FL27499_R4_II_49919 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_49919 Eval.pdf Created by Independent Third Party: Yes |
|
|
| 27499.20 |
DM Class 500 5V Crimp |
26 Ga. galvalume coated steel roof panel, 24" wide, with 5V crimp. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. |
Installation Instructions FL27499_R4_II_49920 Dwg.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499_R4_AE_49920 Eval.pdf Created by Independent Third Party: Yes |