| 10257.1 |
ELDH IZ3 3068 |
Elevate Double Hung - IZ3, Fiberglass Clad Wood Double Hung Window with Impact Glazing, 407-H-783 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-65 Other: Maximum size : 29.5" x 67.75"; Wind Zone 3, Missile level D. All glass conforms to ASTM E1300. Glass make-up is (3.1 mm/7.5 mm air space/ 6.9 mm PVB lami).
Document 00003952 referenced on installation print is for internal use only. |
Certification Agency Certificate FL10257_R10_C_CAC_Marvin407CCL783_75_76.pdf Quality Assurance Contract Expiration Date 03/25/2030 Installation Instructions FL10257_R10_II_Install 783.69 - .76 (00113649) Elevation.pdf FL10257_R10_II_Install 783.69 - .76 (00113650) Method.pdf FL10257_R10_II_Install 783.69.70.73.74 (00052740).pdf FL10257_R10_II_Install 783.69.70.73.74 (00139306).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports FL10257_R10_AE_EvalReport-ELDH.pdf Created by Independent Third Party: Yes |
|
|
| 10257.2 |
ELDH IZ3 3076 |
Elevate Double Hung - IZ3, Fiberglass Clad Wood Double Hung Window with Impact Glazing, 407-H-783 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +55/-65 Other: Maximum size : 29.5" x 75.75"; Wind Zone 3, Missile level D. All glass conforms to ASTM E1300. Glass make-up is (3.1 mm/7.5 mm air space/ 6.9 mm PVB lami).
Document 00003952 referenced on installation print is for internal use only. |
Certification Agency Certificate FL10257_R10_C_CAC_Marvin407CCL783_71_72.pdf Quality Assurance Contract Expiration Date 03/25/2030 Installation Instructions FL10257_R10_II_Install 783.69 - .76 (00113649) Elevation.pdf FL10257_R10_II_Install 783.69 - .76 (00113650) Method.pdf FL10257_R10_II_Install 783.69.70.73.74 (00052740).pdf FL10257_R10_II_Install 783.69.70.73.74 (00139306).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports FL10257_R10_AE_EvalReport-ELDH.pdf Created by Independent Third Party: Yes |
|
|
| 10257.3 |
ELDH IZ3 4268 |
Elevate Double Hung - IZ3, Fiberglass Clad Wood Double Hung Window with Impact Glazing, 407-H-783 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-65 Other: Maximum size : 41.5" x 67.75"; Wind Zone 3, Missile level D. All glass conforms to ASTM E1300. Glass make-up is (3.1 mm/7.5 mm air space/ 6.9 mm PVB lami).
Document 00003952 referenced on installation print is for internal use only. |
Certification Agency Certificate FL10257_R10_C_CAC_Marvin407CCL783_73_74.pdf Quality Assurance Contract Expiration Date 03/25/2030 Installation Instructions FL10257_R10_II_Install 783.69 - .76 (00113649) Elevation.pdf FL10257_R10_II_Install 783.69 - .76 (00113650) Method.pdf FL10257_R10_II_Install 783.69.70.73.74 (00052740).pdf FL10257_R10_II_Install 783.69.70.73.74 (00139306).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports FL10257_R10_AE_EvalReport-ELDH.pdf Created by Independent Third Party: Yes |
|
|
| 10257.4 |
ELDH IZ3 4276 |
Elevate Double Hung - IZ3, Fiberglass Clad Wood Double Hung Window with Impact Glazing, 407-H-783 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-65 Other: Maximum size : 41.5" x 75.75"; Wind Zone 3, Missile level D. All glass conforms to ASTM E1300. Glass make-up is (3.1 mm/7.5 mm air space/ 6.9 mm PVB lami).
Document 00003952 referenced on installation print is for internal use only. |
Certification Agency Certificate FL10257_R10_C_CAC_Marvin407CCL783_69_70.pdf Quality Assurance Contract Expiration Date 03/25/2030 Installation Instructions FL10257_R10_II_Install 783.69 - .76 (00113649) Elevation.pdf FL10257_R10_II_Install 783.69 - .76 (00113650) Method.pdf FL10257_R10_II_Install 783.69.70.73.74 (00052740).pdf FL10257_R10_II_Install 783.69.70.73.74 (00139306).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports FL10257_R10_AE_EvalReport-ELDH.pdf Created by Independent Third Party: Yes |