| 42241.1 |
Premium Atlantic Vinyl |
Stationary Casement (8700F) 36" x 72" Insulated Glass (5/16" SGP Lam in - 1/8" Annealed out) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Windows with insulated glass units wider than 36" require setting blocks. These windows do not meet small missile impact wind-borne requirements as required by FBC, section 2411.3.3.7 when the exterior lite is annealed. These windows meet small missile impact wind-borne protection requirementsas required by FBC, section 2411.3.3.7 when the exterior lite is tempered. Miami-Dade NOAs : Quanex Building Products, Inc PVC (45-1017.02 and 13-0425.15), Dupont SentryGlas interlayer (11-0624.02). |
Certification Agency Certificate FL42241_R1_C_CAC_JELD-WEN - Premium Atl. Vinyl Case. Fixed (1a) (Fin Flange) Impact Mar. 2025 (ext.5) 42241.1.pdf Quality Assurance Contract Expiration Date 08/05/2027 Installation Instructions FL42241_R1_II_D009458 (42241.1) - Premium Atlantic Vinyl Casement 36x72 DP50 Impact FBC Installs_1-21-25 DSS.pdf Verified By: Micah Swartz 93573 Created by Independent Third Party: Yes Evaluation Reports FL42241_R1_AE_SCE 25-03015 - 42241.1 Calcs DSS.pdf Created by Independent Third Party: Yes |
|
|
| 42241.2 |
Premium Atlantic Vinyl |
Stationary Casement (8700F) 47.5" x 71.5" Insulated Glass (5/16" SGP Lam in - 3/16" Annealed out) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Windows with insulated glass units wider than 36" require setting blocks. These windows do not meet small missile impact wind-borne requirements as required by FBC, section 2411.3.3.7 when the exterior lite is annealed. These windows meet small missile impact wind-borne protection requirementsas required by FBC, section 2411.3.3.7 when the exterior lite is tempered. Miami-Dade NOAs : Quanex Building Products, Inc PVC (45-1017.02 and 13-0425.15), Dupont SentryGlas interlayer (11-0624.02). |
Certification Agency Certificate FL42241_R1_C_CAC_JELD-WEN - Premium Atl. Vinyl Case. Fixed (2a) (Fin Flange) Impact Mar. 2025 (ext.5) 42241.2.pdf Quality Assurance Contract Expiration Date 08/05/2027 Installation Instructions FL42241_R1_II_D009458 (42241.2) - Premium Atlantic Vinyl Casement Fixed 47.5x71.5 DP50 Impact FBC Installs_1-21-25 DSS.pdf Verified By: Micah Swartz 93573 Created by Independent Third Party: Yes Evaluation Reports FL42241_R1_AE_SCE 25-03016 - 42241.2 Calcs DSS.pdf Created by Independent Third Party: Yes |