| 42230.1 |
Sunroom Aluminum Double Out-Swing Doors |
Sunroom Aluminum Double Out-Swing Doors |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Operator type HGD. PG40. Glass thickness complies with E1300 and must be a minimum of 1/8" tempered lite. In wind borne debris regions, this product must be used in a room that is physically isolated from the main structure and designed as a partially enclosed structure. If the room is open to the main structure, it must be protected by an impact protection device per FBC. |
Installation Instructions FL42230_R0_II_DS-23-61317 XX Swing Door (2023 FSA) FL42230.1.pdf Verified By: Frank Bennardo, PE 46549 Created by Independent Third Party: Yes Evaluation Reports FL42230_R0_AE_S-23-61317 - FL42230.1 - EVAL.pdf Created by Independent Third Party: Yes |
|
|
| 42230.2 |
Sunroom Aluminum Single In-Swing Doors |
Sunroom Aluminum In-Single Inswing Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Operator type HGD. PG40. Glass thickness complies with E1300 and must be a minimum of 1/8" tempered lite. In wind borne debris regions, this product must be used in a room that is physically isolated from the main structure and designed as a partially enclosed structure. If the room is open to the main structure, it must be protected by an impact protection device per FBC. |
Installation Instructions FL42230_R0_II_DS-23-61317 X In-Swing Door (2023 FSA) FL42230.2.pdf Verified By: Frank Bennardo, PE 46549 Created by Independent Third Party: Yes Evaluation Reports FL42230_R0_AE_S-23-61317 - FL42230.2 - EVAL.pdf Created by Independent Third Party: Yes |
|
|
| 42230.3 |
Sunroom Aluminum Single Out-Swing Doors |
Sunroom Aluminum Single Out-swing Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Operator type HGD. PG50. Glass thickness complies with E1300 and must be a minimum of 1/8" tempered lite. In wind borne debris regions, this product must be used in a room that is physically isolated from the main structure and designed as a partially enclosed structure. If the room is open to the main structure, it must be protected by an impact protection device per FBC. |
Installation Instructions FL42230_R0_II_DS-23-61317 X Out-Swing Door (2023 FSA) FL42230.3.pdf Verified By: Frank Bennardo, PE 46549 Created by Independent Third Party: Yes Evaluation Reports FL42230_R0_AE_S-23-61317 - FL42230.3 - EVAL.pdf Created by Independent Third Party: Yes |