|
|
| 42231.1 |
Series 230 Horizontal Slider HP For Sunroom |
Series 230 Horizontal Slider HP For Sunroom |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Glass must comply with ASTM E1300. In HVHZ, glazing shall be as tested or better [3/4" IG consisting of two lites double strength (1/8") tempered glass, interior glazed onto two part silicone (Tremco S900) to the exterior, and vinyl snap-in bead to the interior, 1/2" glass bite all around]. Product shall be used with an approved impact-resistant covering where required. |
Installation Instructions FL42231_R0_II_DS-23-61338a - 230 HP Horizontal Slider (2023 FSA) FL42231.1.pdf Verified By: Frank Bennardo, PE 46549 Created by Independent Third Party: Yes Evaluation Reports FL42231_R0_AE_S-23-61338 - FL42231.1 - EVAL.pdf Created by Independent Third Party: Yes |
|
|
| 42231.2 |
Series 230 Horizontal Sliding Window for Sunroom |
Series 230 Horizontal Sliding Window for Sunroom |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: HS-LC40-72"x58" Four Seasons approved installation only. Glass thickness complies with E1300. This product is not designed for use in the HVHZ. In wind borne debris regions, this product must be used in a room that is physically isolated from the main structure and is designed as a partially enclosed structure, unless impact protection is provided. |
Installation Instructions FL42231_R0_II_DS-23-61338b - 230 HP Horizontal Slider (2023 FSA) FL42231.2.pdf Verified By: Frank Bennardo, PE 46549 Created by Independent Third Party: Yes Evaluation Reports FL42231_R0_AE_S-23-61338 - FL42231.2 - EVAL.pdf Created by Independent Third Party: Yes |