Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL42234-R2
Application Type Revision
Code Version 2026
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Jeld-Wen
Address/Phone/Email 3737 Lakeport Blvd
Klamath Falls, OR 97601
(541) 850-2650
FBC1@jeldwen.com
 
Authorized Signature Rylee Fricks
FBC1@jeldwen.com
 
Technical Representative JELD-WEN Customer Experience
Address/Phone/Email 3737 Lakeport Blvd
Klamath Falls, OR 97601
(800) 535-3936
CustomerServiceUS@jeldwen.com
 
Quality Assurance Representative
Address/Phone/Email
 
Category Windows
Subcategory Awning
 
Compliance Method Certification Mark or Listing
 
Certification Agency Fenestration and Glazing Industry Alliance (formerly AAMA)
Validated By Fenestration and Glazing Industry Alliance (formerly AAMA)
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA/CSA 101/I.S.2/A4402017
TAS 2011994
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 07/01/2026
Date Validated 09/09/2026
Date Pending FBC Approval
Date Approved 09/09/2026
 
Summary of Products
FL # Model, Number or Name Description
42234.1 Premium Atlantic Vinyl Awning (8800) 48" x 32" Insulated Glass (1/8" Annealed - 5/16" SGP Lam)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: Lam. glazing interlayer and White ridged PVC ext. extrusion requirement meet the current FBC.Windows with IG wider than 36" require setting blocks.Ext. glazing must be tempered above 30ft.These windows meet SMI windborne requirement as required by FBC section 2411.3.3.7 when the ext. lite is tempered.Miami-Dade NOAs:Quanex Building Products, Inc PVC12-1017.02and13-0425.15,Dupont PVB Interlayer(13-0129.27).Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC
Certification Agency Certificate
 FL42234_R2_C_CAC_JELD-WEN - Premium Atl. Vinyl Awning (1b) (Fin Flange) Impact Mar. 2026 (ext.5) 42234.1.pdf
Quality Assurance Contract Expiration Date
 04/03/2030
Installation Instructions
 FL42234_R2_II_D1000507 (42234.1) - Premium Atlantic Vinyl Awning - Impact 48.75x32.75 DP50 FBC Installs_1-21-25 DSS.pdf
 Verified By: Micah Swartz 93573
 Created by Independent Third Party: Yes
Evaluation Reports
 FL42234_R2_AE_SCE 25-03011 - 42234.1 Calcs R1 Admin DSS.pdf