Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL13308-R9
Application Type Revision
Code Version 2023
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Velux America, LLC
Address/Phone/Email P.O. Box 5001
Greenwood, SC 29648
(941) 400-6013
alan@kinneec.com
 
Authorized Signature Mike Rhoden
Mike.rhoden@velux.com
 
Technical Representative Mike Rhoden
Address/Phone/Email 104 Ben Casey Dr
Fort Mill, SC 29708
(864) 377-0691
mike.rhoden@velux.com
 
Quality Assurance Representative Mike Rhoden
Address/Phone/Email 104 Ben Casey Drive
Fort Mill, SC 29708
(803) 396-5736
mike.rhoden@velux.com
 
Category Sky Lights
Subcategory Skylight
 
Compliance Method Certification Mark or Listing
 
Certification Agency Window and Door Manufacturer Association
Validated By Window and Door Manufacturers Association
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA/CSA 101/I.S.2/A4402017
AAMA/WDMA/CSA 101/I.S.2/A4402011
ASTM E 188613
ASTM E 199614
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL13308_R9_Equiv_FL 13308.5 ASTM EQ.pdf
FL13308_R9_Equiv_FL 13308.6 ASTM EQ.pdf
 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 03/04/2025
Date Validated 03/24/2025
Date Pending FBC Approval
Date Approved 03/25/2025
 
Summary of Products
FL # Model, Number or Name Description
13308.1 FS [_04, _08, _14 or _89] Aluminum-clad Deck Mount Fixed Skylight, size S06 and smaller (426-H-672.43)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +330/-70
 Other: SKG-PG70, max. size 1130mm x 1162mm. PG70 means minimum capacity is 70 psf. Glass meets ASTM E1300: 3mm clear tempered / 8.5mm st. stl. spacer / 5.7mm laminate using two 2.5mm heat-strengthened panes and 0.030" PVB interlayer (with white coating for _08 variant; with second Lo-E coating for _89 variant).
Certification Agency Certificate
 FL13308_R9_C_CAC_FL13308 FS S06 or smaller 04, 08, 14 or 89.pdf
Quality Assurance Contract Expiration Date
 07/02/2031
Installation Instructions
 FL13308_R9_II_Additional Anchorage Details.pdf
 FL13308_R9_II_FS Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
13308.2 FS [_04, _08, _14 or _89] Aluminum-clad Deck Mount Fixed Skylight, size M08 and smaller (426-H-672.46)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +240/-105
 Other: SKG-PG105, max. size 768mm x 1390mm. PG105 means minimum capacity is 105 psf. Glass meets ASTM E1300: 3mm clear tempered / 8.5mm st. stl. spacer / 5.7mm laminate using two 2.5mm heat-strengthened panes and 0.030" PVB interlayer (with white coating for _08 variant; with second Lo-E coating for _89 variant).
Certification Agency Certificate
 FL13308_R9_C_CAC_FL13308 FS M08 or smaller 04, 08, 14 or 89.pdf
Quality Assurance Contract Expiration Date
 07/02/2031
Installation Instructions
 FL13308_R9_II_Additional Anchorage Details.pdf
 FL13308_R9_II_FS Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
13308.3 FS [_05, _15 or _88] Aluminum-clad Deck Mount Fixed Skylight, size S06 and smaller (426-H-672.37)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +250/-45
 Other: SKG-PG45, max. size 1130mm x 1162mm. PG45 means minimum capacity is 45 psf. Glass meets ASTM E1300: 3mm clear tempered / 10.5mm st. stl. spacer / 3mm clear tempered (with second Lo-E coating for _88 variant).
Certification Agency Certificate
 FL13308_R9_C_CAC_FL13308 FS S06 or smaller 05, 15 or 88.pdf
Quality Assurance Contract Expiration Date
 07/02/2031
Installation Instructions
 FL13308_R9_II_Additional Anchorage Details.pdf
 FL13308_R9_II_FS Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
13308.4 FS [_05, _15 or _88] Aluminum-clad Deck Mount Fixed Skylight, size M08 and smaller (426-H-672.40)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +400/-105
 Other: SKG-PG105, max. size 768mm x 1390mm. PG105 means minimum capacity is 105 psf. Glass meets ASTM E1300: 3mm clear tempered / 10.5mm st. stl. spacer / 3mm clear tempered (with second Lo-E coating for _88 variant).
Certification Agency Certificate
 FL13308_R9_C_CAC_FL13308 FS M08 or smaller 05, 15 or 88.pdf
Quality Assurance Contract Expiration Date
 07/02/2031
Installation Instructions
 FL13308_R9_II_Additional Anchorage Details.pdf
 FL13308_R9_II_FS Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
13308.5 FS _06 or _16 [Impact Resistant] Aluminum-clad Deck Mount Fixed Skylight, size S06 and smaller (426-H-672.58)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50 & Design Pressure +180/-50 psf, SKG-PG50, max. size 1137mm x 1175mm. This model tested for cycling pursuant to ASTM E 1996 and ASTM E 1886. Glass meets ASTM E1300: 3mm clear tempered / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm heat-strengthened panes and three 0.030" PVB interlayers. Both IGU and frame use silicone glass sealant.
Certification Agency Certificate
 FL13308_R9_C_CAC_FL13308 FS S06 or smaller 06 or 16.pdf
Quality Assurance Contract Expiration Date
 04/15/2031
Installation Instructions
 FL13308_R9_II_Additional Anchorage Details.pdf
 FL13308_R9_II_FS Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
13308.6 FS _06 or _16 [Impact Resistant] Aluminum-clad Deck Mount Fixed Skylight, size M08 and smaller (426-H-672.62)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +70/-70
 Other: Wind Zone 3, Missile Level C, Cycle Pressure +70/-70 & Design Pressure +200/-90 psf, SKG-PG90, max. size 781mm x 1397mm. This model tested for cycling pursuant to ASTM E 1996 and ASTM E 1886. Glass meets ASTM E1300: 3mm clear tempered / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm heat-strengthened panes and three 0.030" PVB interlayers. Both IGU and frame use silicone glass sealant.
Certification Agency Certificate
 FL13308_R9_C_CAC_FL13308 FS M08 or smaller 06 or 16.pdf
Quality Assurance Contract Expiration Date
 04/15/2031
Installation Instructions
 FL13308_R9_II_Additional Anchorage Details.pdf
 FL13308_R9_II_FS Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex