| 13308.1 |
FS [_04, _08, _14 or _89] |
Aluminum-clad Deck Mount Fixed Skylight, size S06 and smaller
(426-H-672.43) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +330/-70 Other: SKG-PG70, max. size 1130mm x 1162mm.
PG70 means minimum capacity is 70 psf. Glass meets ASTM E1300: 3mm clear tempered / 8.5mm st. stl. spacer / 5.7mm laminate using two 2.5mm heat-strengthened panes and 0.030" PVB interlayer (with white coating for _08 variant; with second Lo-E coating for _89 variant). |
Certification Agency Certificate FL13308_R9_C_CAC_FL13308 FS S06 or smaller 04, 08, 14 or 89.pdf Quality Assurance Contract Expiration Date 07/02/2031 Installation Instructions FL13308_R9_II_Additional Anchorage Details.pdf FL13308_R9_II_FS Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 13308.2 |
FS [_04, _08, _14 or _89] |
Aluminum-clad Deck Mount Fixed Skylight, size M08 and smaller (426-H-672.46) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +240/-105 Other: SKG-PG105, max. size 768mm x 1390mm. PG105 means minimum capacity is 105 psf. Glass meets ASTM E1300: 3mm clear tempered / 8.5mm st. stl. spacer / 5.7mm laminate using two 2.5mm heat-strengthened panes and 0.030" PVB interlayer (with white coating for _08 variant; with second Lo-E coating for _89 variant). |
Certification Agency Certificate FL13308_R9_C_CAC_FL13308 FS M08 or smaller 04, 08, 14 or 89.pdf Quality Assurance Contract Expiration Date 07/02/2031 Installation Instructions FL13308_R9_II_Additional Anchorage Details.pdf FL13308_R9_II_FS Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 13308.3 |
FS [_05, _15 or _88] |
Aluminum-clad Deck Mount Fixed Skylight, size S06 and smaller (426-H-672.37) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +250/-45 Other: SKG-PG45, max. size 1130mm x 1162mm.
PG45 means minimum capacity is 45 psf. Glass meets ASTM E1300: 3mm clear tempered / 10.5mm st. stl. spacer / 3mm clear tempered (with second Lo-E coating for _88 variant). |
Certification Agency Certificate FL13308_R9_C_CAC_FL13308 FS S06 or smaller 05, 15 or 88.pdf Quality Assurance Contract Expiration Date 07/02/2031 Installation Instructions FL13308_R9_II_Additional Anchorage Details.pdf FL13308_R9_II_FS Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 13308.4 |
FS [_05, _15 or _88] |
Aluminum-clad Deck Mount Fixed Skylight, size M08 and smaller (426-H-672.40) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +400/-105 Other: SKG-PG105, max. size 768mm x 1390mm. PG105 means minimum capacity is 105 psf. Glass meets ASTM E1300: 3mm clear tempered / 10.5mm st. stl. spacer / 3mm clear tempered (with second Lo-E coating for _88 variant). |
Certification Agency Certificate FL13308_R9_C_CAC_FL13308 FS M08 or smaller 05, 15 or 88.pdf Quality Assurance Contract Expiration Date 07/02/2031 Installation Instructions FL13308_R9_II_Additional Anchorage Details.pdf FL13308_R9_II_FS Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 13308.5 |
FS _06 or _16 [Impact Resistant] |
Aluminum-clad Deck Mount Fixed Skylight, size S06 and smaller (426-H-672.58) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50 & Design Pressure +180/-50 psf, SKG-PG50, max. size 1137mm x 1175mm.
This model tested for cycling pursuant to ASTM E 1996 and ASTM E 1886.
Glass meets ASTM E1300: 3mm clear tempered / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm heat-strengthened panes and three 0.030" PVB interlayers. Both IGU and frame use silicone glass sealant. |
Certification Agency Certificate FL13308_R9_C_CAC_FL13308 FS S06 or smaller 06 or 16.pdf Quality Assurance Contract Expiration Date 04/15/2031 Installation Instructions FL13308_R9_II_Additional Anchorage Details.pdf FL13308_R9_II_FS Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 13308.6 |
FS _06 or _16 [Impact Resistant] |
Aluminum-clad Deck Mount Fixed Skylight, size M08 and smaller (426-H-672.62) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: Wind Zone 3, Missile Level C, Cycle Pressure +70/-70 & Design Pressure +200/-90 psf, SKG-PG90, max. size 781mm x 1397mm.
This model tested for cycling pursuant to ASTM E 1996 and ASTM E 1886.
Glass meets ASTM E1300: 3mm clear tempered / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm heat-strengthened panes and three 0.030" PVB interlayers.
Both IGU and frame use silicone glass sealant. |
Certification Agency Certificate FL13308_R9_C_CAC_FL13308 FS M08 or smaller 06 or 16.pdf Quality Assurance Contract Expiration Date 04/15/2031 Installation Instructions FL13308_R9_II_Additional Anchorage Details.pdf FL13308_R9_II_FS Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |