| 13300.1 |
QPF [2004 or 2008 or 2014 or 2089] |
Pan Flashed Fixed Skylight, size 4646 and smaller
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +160/-60 Other: SKG-PG60, max. size 1219mm x 1219mm. PG60 means minimum capacity is 60 psf. Glass meets ASTM E1300: 3mm clear tempered with Lo-E366 (or Lo-E340 for 2014 variant) on surface 2 / 8.5mm st. stl. spacer / 5.7mm laminate using two 2.5mm heat-strengthened panes and 0.030" PVB interlayer (with white coating for 2008 variant; with second Lo-E coating on surface 4 for 2089 variant). For anchorage details, see installation instructions. |
Certification Agency Certificate FL13300_R13_C_CAC_FL 13300 QPF [4646 or smaller] 04-08-14-89_non-impact.pdf Quality Assurance Contract Expiration Date 01/13/2031 Installation Instructions FL13300_R13_II_FL13300 QPF Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 13300.2 |
QPF [2005 or 2015 or 2088] |
Pan Flashed Fixed Skylight, size 4646 and smaller |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +160/-60 Other: SKG-PG60, max. size 1219mm x 1219mm. PG60 means minimum capacity is 60 psf. Glass meets ASTM E1300: 3mm clear tempered with Lo-E366 (or Lo-E340 for 2015 variant) on surface 2 / 10.5mm st. stl. spacer / 3mm clear tempered (with second Lo-E coating on surface 4 for 2088 variant). For anchorage details, see installation instructions. |
Certification Agency Certificate FL13300_R13_C_CAC_FL 13300 QPF [4646 or smaller] 05-15-88_non-impact.pdf Quality Assurance Contract Expiration Date 01/13/2031 Installation Instructions FL13300_R13_II_FL13300 QPF Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 13300.3 |
QPF [2006 or 2016 or 2017] (HVHZ) |
Pan Flashed Fixed Skylight, size 4646 and smaller |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +120/-50 Other: Wind Zone 4, Missile Level D, Cycle Pressure +50/-50, max. size 1219mm x 1219mm. This model was tested for cycling pursuant to ASTM standards. Glass meets ASTM E1300: 3mm clear tempered with Lo-E366 (or Lo-E340 for 2016 variant) on surface 2 / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm heat-strengthened panes and three 0.030" PVB interlayers. For anchorage details, see Page 6 of instructions. |
Certification Agency Certificate FL13300_R13_C_CAC_FL13300 QPF [4646 or smaller] 0006 or 0016 or 0017 Impact.pdf Quality Assurance Contract Expiration Date 11/18/2030 Installation Instructions FL13300_R13_II_FL13300 QPF Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |