Product Approval Menu > Application Detail
 
FL # FL13303-R12
Application Type Revision
Code Version 2023
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Velux America, LLC
Address/Phone/Email P.O. Box 5001
Greenwood, SC 29648
(941) 400-6013
alan@kinneec.com
 
Authorized Signature Mike Rhoden
Mike.rhoden@velux.com
 
Technical Representative Mike Rhoden
Address/Phone/Email 104 Ben Casey Dr
Fort Mill, SC 29708
(864) 377-0691
mike.rhoden@velux.com
 
Quality Assurance Representative Mike Rhoden
Address/Phone/Email 104 Ben Casey Drive
Fort Mill, SC 29708
(803) 396-5736
mike.rhoden@velux.com
 
Category Sky Lights
Subcategory Skylight
 
Compliance Method Certification Mark or Listing
 
Certification Agency Window and Door Manufacturer Association
Validated By Window and Door Manufacturers Association
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA/CSA 101/I.S.2/A4402017
AAMA/WDMA/CSA 101/I.S.2/A4402011
ASTM E 18862013
ASTM E 19962014
TAS 2011994
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL13303_R12_Equiv_FL 13303 ASTM EQ.pdf
 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 09/29/2025
Date Validated 09/30/2025
Date Pending FBC Approval
Date Approved 10/01/2025
 
Summary of Products
FL # Model, Number or Name Description
13303.1 FCM [04 or 08 or 14 or 29 or 89] Aluminum Curb Mount Fixed Skylight, size 4646 and smaller (426-H-701.51/.52)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +175/-120
 Other: SKG-PG120, max. size 1301.75mm x 1301.75mm (51.25" x 51.25"). PG120 means minimum capacity is 120 psf. Glass meets ASTM E1300: 3.9mm clear tempered / 8.5mm st. stl. spacer / 5.7mm laminate using two 2.5mm panes and 0.030" PVB interlayer (with white coating for 08 variant; with second Lo-E coating for 29 variant). Anchoring to site-built curb: three screws per side for longest members and two per side for shorter members, filling all pre-punched holes with supplied screws.
Certification Agency Certificate
 FL13303_R12_C_CAC_FL13303 FCM 4646 or smaller 04 or 08 or 14 or 29 or 89.pdf
Quality Assurance Contract Expiration Date
 03/05/2031
Installation Instructions
 FL13303_R12_II_FL13303 FCM Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
13303.2 FCM [04 or 08 or 14 or 29 or 89] Aluminum Curb Mount Fixed Skylight, size 2270 and smaller (426-H-701.43/.44)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +200/-100
 Other: SKG-PG100, max. size 660mm x 1854mm (25.98" x 72.99"). PG100 means min. capacity is 100 psf. Glass meets ASTM E1300: 3.9mm clear tempered with Lo-E366 (or Lo-E340 for 14 variant) on surface 2 / 8.5mm st. stl. spacer / 5.7mm laminate using two 2.5mm panes and 0.030" PVB interlayer (white for 08); with 2nd Lo-E coating on surface 4 for 29. Anchoring to site-built curb: 3 screws/side for longest members and 2/side for shorter members, fill all pre-punched holes with supplied screws
Certification Agency Certificate
 FL13303_R12_C_CAC_FL13303 FCM 2270 or smaller 04 or 08 or 14 or 29 or 89.pdf
Quality Assurance Contract Expiration Date
 03/05/2031
Installation Instructions
 FL13303_R12_II_FL13303 FCM Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
13303.3 FCM [04 or 08 or 14 or 29 or 89] Aluminum Curb Mount Fixed Skylight, size 4672 and smaller (426-H-701.47/.48)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +70/-80
 Other: SKG-PG70, max. size 1308mm x 1960mm (51.49" x 51.49"). PG70 means minimum capacity is 70 psf. Glass meets ASTM E1300: 3.9mm clear tempered / 8.5mm st. stl. spacer / 5.7mm laminate using two 2.5mm panes and 0.030" PVB interlayer (with white coating for 08 variant; with second Lo-E coating for 29 variant). Anchoring to site-built curb: five screws per side for longest members and three per side for shorter members, filling all pre-punched holes with supplied screws.
Certification Agency Certificate
 FL13303_R12_C_CAC_FL13303 FCM 4672 or smaller 04 or 08 or 14 or 29 or 89.pdf
Quality Assurance Contract Expiration Date
 03/05/2031
Installation Instructions
 FL13303_R12_II_FL13303 FCM Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
13303.4 FCM [05 or 05C or 15 or 30 or 88] Aluminum Curb Mount Fixed Skylight, size 4646 and smaller (426-H-701.23/.24)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +140/-140
 Other: SKG-PG140, max. size 1301.75mm x 1301.75mm (51.25" x 51.25"). PG140 means minimum capacity is 140 psf. Glass meets ASTM E1300: 3.9mm clear tempered with Lo-E366 (or Lo-E340 for 15 variant) on surface 2 / 10.5mm st. stl. spacer / 3.9mm clear tempered; (with 2nd Lo-E coating on surface 4 for 30 variant). Anchoring to site-built curb: 3 screws/side for longest members and 2/side for shorter members, fill all pre-punched holes with supplied screws.
Certification Agency Certificate
 FL13303_R12_C_CAC_FL13303 FCM 4646 or smaller 05 or 05C or 15 or 30 or 88.pdf
Quality Assurance Contract Expiration Date
 03/05/2031
Installation Instructions
 FL13303_R12_II_FL13303 FCM Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
13303.5 FCM [06 or 16] (HVHZ) Aluminum Curb Mount Fixed Skylight, size 2246 and smaller (426-H-701.37/.38/.41/.42)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +150/-120
 Other: Wind Zone 4, Missile D, Cycle Press. +50/-50, max. size 648mm x 1257mm (25.51" x 49.48"). Tested ASTM E1886/ASTM E1996, TAS 201/202/203. Glass meets ASTM E1300: 3.9mm clear tempered with Lo-E366 (or Lo-E340 for 16 variant) on surface 2 / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm panes and three 0.030" PVB interlayers. Anchoring to site-built curb: 3 screws/side for longest members & 2/side for shorter members. Fill all pre-punched holes with supplied screws.
Certification Agency Certificate
 FL13303_R12_C_CAC_FL13303 FCM 2246 or smaller 06 or 16.pdf
Quality Assurance Contract Expiration Date
 02/23/2031
Installation Instructions
 FL13303_R12_II_FL13303 FCM Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
13303.6 FCM [06 or 16] (HVHZ) Aluminum Curb Mount Fixed Skylight, size 4646 and smaller (426-H-701.27/.28/.31/.32)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +125/-80
 Other: Wind Zone 4, Missile D, Cycle Press. +50/-50, max size 1308mm x 1308mm (51.49" x 51.49"). Tested ASTM E1886/E1996, TAS 201/202/203. Glass meets ASTM E1300: 3.9mm clear tempered with Lo-E366 (or Lo-E340 for 16 variant) on surface 2 / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm panes and three 0.030" PVB interlayers. Anchoring to site-built curb: 3 screws/side for longest members & 2/side for shorter members. Fill all pre-punched holes with supplied screws.
Certification Agency Certificate
 FL13303_R12_C_CAC_FL13303 FCM 4646 or smaller 6 or 16.pdf
Quality Assurance Contract Expiration Date
 02/23/2031
Installation Instructions
 FL13303_R12_II_FL13303 FCM Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
 