| 13309.1 |
[VS or VSE or VSS] [_04, _08, _14 or _89] |
Aluminum-clad Deck Mount Venting Skylight, size S06 and smaller (426-H-670.37) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +300/-65 Other: SKG-PG65, max. size 1194mm x 1238mm. PG65 means minimum capacity is 65 psf.
Glass meets ASTM E1300: 3mm clear tempered / 8.5mm st. stl. spacer / 5.7mm laminate using two 2.5mm heat-strengthened panes and 0.030" PVB interlayer (with white coating for _08 variants; with second Lo-E coating for _89 variants). |
Certification Agency Certificate FL13309_R8_C_CAC_FL13309 VS, VSE, VSS S06 or smaller 04, 08, 14 or 89.pdf Quality Assurance Contract Expiration Date 03/09/2031 Installation Instructions FL13309_R8_II_Additional Anchorage Details.pdf FL13309_R8_II_VS_VSE Installation Instructions.pdf FL13309_R8_II_VSS Installation Instruction.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 13309.2 |
[VS or VSE or VSS] [_04, _08, _14 or _89] |
Aluminum-clad Deck Mount Venting Skylight, size M08 and smaller (426-H-670.40) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +400/-105 Other: SKG-PG105, max. size 800mm x 1422mm. PG105 means minimum capacity is 105 psf. Glass meets ASTM E1300: 3mm clear tempered / 8.5mm st. stl. spacer / 5.7mm laminate using two 2.5mm heat-strengthened panes and 0.030" PVB interlayer (with white coating for _08 variants; with second Lo-E coating for _89 variants). |
Certification Agency Certificate FL13309_R8_C_CAC_FL13309 VS, VSE, VSS M08 or smaller 04, 08, 14 or 89.pdf Quality Assurance Contract Expiration Date 03/09/2031 Installation Instructions FL13309_R8_II_Additional Anchorage Details.pdf FL13309_R8_II_VS_VSE Installation Instructions.pdf FL13309_R8_II_VSS Installation Instruction.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 13309.3 |
[VS or VSE or VSS] [_06 or _16] Impact Resistant |
Aluminum-clad Deck Mount Venting Skylight, size S06 and smaller (426-H-670.56) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50 & Design Pressure +200/-67 psf, max. size 1200mm x 1226mm. This model was tested for cycling pursuant to ASTM E1886 and ASTM E1996. Glass meets ASTM E1300: 3mm clear tempered / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm heat-strengthened panes and three 0.030" PVB interlayers. |
Certification Agency Certificate FL13309_R8_C_CAC_FL13309 VS, VSE, VSS S06 or smaller 06 or 16.pdf Quality Assurance Contract Expiration Date 05/04/2031 Installation Instructions FL13309_R8_II_Additional Anchorage Details.pdf FL13309_R8_II_VS_VSE Installation Instructions.pdf FL13309_R8_II_VSS Installation Instruction.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 13309.4 |
[VS or VSE or VSS] [_06 or _16] Impact Resistant |
Aluminum-clad Deck Mount Venting Skylight, size M08 and smaller (426-H-670.46) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50 & Design Pressure +230/-67 psf, max. size 845mm x 1461mm. This model was tested for cycling pursuant to ASTM E1886 and ASTM E1996. Glass meets ASTM E1300: 3mm clear tempered / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm heat-strengthened panes and three 0.030" PVB interlayers. |
Certification Agency Certificate FL13309_R8_C_CAC_FL13309 VS, VSE, VSS M08 or smaller 06 or 16.pdf Quality Assurance Contract Expiration Date 05/04/2031 Installation Instructions FL13309_R8_II_Additional Anchorage Details.pdf FL13309_R8_II_VS_VSE Installation Instructions.pdf FL13309_R8_II_VSS Installation Instruction.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |