| 47082.1 |
01 QUICK-SHIELD 155-2.5 |
Spray Polyurethane Foam Roof System - Recover Application over Modified Bitumen Roof System Support: Plywood Deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-67.5 Other: Refer to evaluation report for conditions and limitations of use |
Installation Instructions FL47082_R0_II_01_24-700-MB-PLY-ER7.pdf Verified By: James L. Buckner P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL47082_R0_AE_01_24-700-MB-PLY-ER7.pdf Created by Independent Third Party: Yes |
|
|
| 47082.2 |
02 QUICK-SHIELD 155-2.5 |
Spray Polyurethane Foam Roof System Recover Application over Modified Bitumen Roof System Support: Steel Deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-330 Other: Refer to evaluation report for conditions and limitations of use |
Installation Instructions FL47082_R0_II_02_24-700-MB-STL-ER7.pdf Verified By: James L. Buckner P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL47082_R0_AE_02_24-700-MB-STL-ER7.pdf Created by Independent Third Party: Yes |
|
|
| 47082.3 |
03 QUICK-SHIELD 155-2.5 |
Spray Polyurethane Foam Roof System Recover Application over Modified Bitumen Roof System Support: Concrete Deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-330 Other: Refer to evaluation report for conditions and limitations of use |
Installation Instructions FL47082_R0_II_03_24-700-MB-CONC-ER7.pdf Verified By: James L. Buckner P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL47082_R0_AE_03_24-700-MB-CONC-ER7.pdf Created by Independent Third Party: Yes |
|
|
| 47082.4 |
04 QUICK-SHIELD 155-2.5 |
Spray Polyurethane Foam Roof System Recover Application over BUR-Smooth Roof System Support: Steel Deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-300 Other: Refer to evaluation report for conditions and limitations of use |
Installation Instructions FL47082_R0_II_04_24-700-BUR-S-STL-ER7.pdf Verified By: James L. Buckner P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL47082_R0_AE_04_24-700-BUR-S-STL-ER7.pdf Created by Independent Third Party: Yes |
|
|
| 47082.5 |
05 QUICK-SHIELD 155-2.5 |
Spray Polyurethane Foam Roof System Recover Application over BUR-Gravel Roof System Support: Steel Deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-300 Other: Refer to evaluation report for conditions and limitations of use |
Installation Instructions FL47082_R0_II_05_24-700-BUR-G-STL-ER7.pdf Verified By: James L. Buckner P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL47082_R0_AE_05_24-700-BUR-G-STL-ER7.pdf Created by Independent Third Party: Yes |
|
|
| 47082.6 |
06 QUICK-SHIELD 155-2.5 |
Spray Polyurethane Foam Roof System Recover Application over BUR-Smooth Roof System Support: Concrete Deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-300 Other: Refer to evaluation report for conditions and limitations of use |
Installation Instructions FL47082_R0_II_06_24-700-BUR-S-CONC-ER7.pdf Verified By: James L. Buckner P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL47082_R0_AE_06_24-700-BUR-S-CONC-ER7.pdf Created by Independent Third Party: Yes |
|
|
| 47082.7 |
07 QUICK-SHIELD 155-2.5 |
Spray Polyurethane Foam Roof System Recover Application over BUR-Gravel Roof System Support: Concrete Deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-300 Other: Refer to evaluation report for conditions and limitations of use |
Installation Instructions FL47082_R0_II_07_24-700-BUR-G-CONC-ER7.pdf Verified By: James L. Buckner P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL47082_R0_AE_07_24-700-BUR-G-CONC-ER7.pdf Created by Independent Third Party: Yes |