Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL14217-R9
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer YKK AP America
Address/Phone/Email 1229 Hwy 441 Bypass
Dublin, GA 31021
(678) 838-6044
heatherevans@ykkap.com
 
Authorized Signature Hermes Norero
fbc@buildingdrops.com
 
Technical Representative Heather Evans
Address/Phone/Email 1229 Hwy 441 Bypass
Dublin, GA 31021
(678) 838-6044
heatherevans@ykkap.com
 
Quality Assurance Representative Heather Evans
Address/Phone/Email 1229 Hwy 441 Bypass
Dublin, GA 31021
(678) 838-6044
heatherevans@ykkap.com
 
Category Panel Walls
Subcategory Curtain Walls
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Hermes F. Norero, P.E.
Florida License PE-73778
Quality Assurance Entity Architectural Testing, Inc., an Intertek Company
Quality Assurance Contract Expiration Date 12/31/2026
Validated By Zachary R. Priest, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL14217_R9_COI_COI_YKK AP America, Inc. SS 2024-02-28.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA 5012015
TAS 2011994
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 06/04/2026
Date Validated 06/09/2026
Date Pending FBC Approval 06/10/2026
Date Approved 08/11/2026
Date Revised 08/11/2026
 
Summary of Products
FL # Model, Number or Name Description
14217.1 YHC 300 IG Curtain Wall (HVHZ) (Impact) YHC 300 IG Curtain Wall (HVHZ) (Impact)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: See Installation Instructions and Evaluation Report for allowable design pressures, sizes, configurations installation requirements and limits of use.
Installation Instructions
 FL14217_R9_II_YKK211 SS 2026-06-03.pdf
 Verified By: Hermes F. Norero 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14217_R9_AE_PER10849 SS 2026-06-03.pdf
 FL14217_R9_AE_YHC 300 IG - Gasket Letter.pdf
 Created by Independent Third Party: Yes
14217.2 YHC 300 IG Curtain Wall (WZ3) (Impact) YHC 300 IG Curtain Wall (WZ3) (Impact)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: See Installation Instructions and Evaluation Report for allowable design pressures, sizes, configurations installation requirements and limits of use.
Installation Instructions
 FL14217_R9_II_YKK212 SS 2026-06-03.pdf
 Verified By: Hermes F. Norero, P.E. Florida P.E. 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14217_R9_AE_PER10850 SS 2026-06-03.pdf
 FL14217_R9_AE_YHC 300 IG - Gasket Letter.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 