14210.1 |
1 - "Cee-Lock" Panel |
Snap-Lock, Structural Roof Panel 24 Ga. Steel, restrained by continuous “Cee-Rib” panel clips, attached to steel purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-52.5 Other: Refer to Evaluation Report for Conditions & Limitations of Use. Refer to manufacturer's installation instructions as a supplemental guide. |
Installation Instructions FL14210_R7_II_1_CeeLock_24ga_SteelPurlins_EVALREPORT_.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL14210_R7_AE_1_CeeLock_24ga_SteelPurlins_EVALREPORT_.pdf Created by Independent Third Party: Yes |
|
14210.2 |
2 - "Cee-Lock" Panel |
Snap-Lock, Structural Roof Panel 22 Ga. Steel, restrained by continuous “Cee-Rib” panel clips, attached to steel purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-150 max. Other: Refer to Evaluation Report for Conditions & Limitations of Use. Refer to manufacturer's installation instructions as a supplemental guide. |
Installation Instructions FL14210_R7_II_2_CeeLock_22ga_SteelPurlins_EVALREPORT_.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL14210_R7_AE_2_CeeLock_22ga_SteelPurlins_EVALREPORT_.pdf Created by Independent Third Party: Yes |
|
14210.3 |
3 - "Zee-Lock" Panel |
Standing Seam, Structural Roof Panel 24 Ga. Steel, restrained by continuous “Zee-Rib” panel clips or "Zee Clip" slider clips, mechanically seamed, attached to steel purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-120 max. Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment. |
Installation Instructions FL14210_R7_II_3_ZeeLock_24ga_SteelPurlins_EVALREPORT_.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL14210_R7_AE_3_ZeeLock_24ga_SteelPurlins_EVALREPORT_.pdf Created by Independent Third Party: Yes |
|
14210.4 |
4 - "Double-Lock Zee-Lock" Panel |
Standing Seam, Structural Roof Panel
22 Ga. Steel, restrained by continuous “Zee-Rib” panel clips, mechanically seamed 180 degrees, attached to steel purlins
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-140 max. Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment. |
Installation Instructions FL14210_R7_II_4_ZeeLock_22ga_SteelPurlins_EVALREPORT_.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL14210_R7_AE_4_ZeeLock_22ga_SteelPurlins_EVALREPORT_.pdf Created by Independent Third Party: Yes |
|
14210.5 |
5 - "Deep Deck" Panel |
Lapped, Structural Roof Panel 24 Ga.or 22 Ga.Steel, attached to steel purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-182 max. Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment. |
Installation Instructions FL14210_R7_II_5_DeepDeck_SteelPurlins_EVALREPORT_.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL14210_R7_AE_5_DeepDeck_SteelPurlins_EVALREPORT_.pdf Created by Independent Third Party: Yes |
|
14210.6 |
7 - "M-Panel" |
Lapped, Structural Roof Panel 26 Ga. or 24 Ga. Steel, attached to steel purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-52.5 Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment. |
Installation Instructions FL14210_R7_II_6_MPanel_SteelPurlins_EVALREPORT_.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL14210_R7_AE_6_MPanel_SteelPurlins_EVALREPORT_.pdf Created by Independent Third Party: Yes |
|
14210.7 |
8 - "R-Panel" |
Lapped, Structural Roof Panel 26 Ga. or 24 Ga. Steel, attached to steel purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-52.5 Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment. |
Installation Instructions FL14210_R7_II_7_RPanel_SteelPurlins_EVALREPORT_.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL14210_R7_AE_7_RPanel_SteelPurlins_EVALREPORT_.pdf Created by Independent Third Party: Yes |
|
14210.8 |
9 - "S-Deck" or "Curved S-Deck" Pane |
Lapped, Structural Roof Panel 24 Ga. Steel, attached to steel purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-190 max. Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment. |
Installation Instructions FL14210_R7_II_8_SDeck_or_CurvedSDeck_SteelPurlins_EVALREPORT_.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL14210_R7_AE_8_SDeck_or_CurvedSDeck_SteelPurlins_EVALREPORT_.pdf Created by Independent Third Party: Yes |
|
14210.9 |
9- "Double-Lock Zee-Lock" Panel |
Standing Seam, Structural Roof Panel 22 Ga. Steel, restrained by continuous 3" “Zee-Rib” panel clips, mechanically seamed 180 degrees, attached to steel purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-140 max Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment. |
Installation Instructions FL14210_R7_II_9_ZeeLock_22ga_InsulSteelPurlins_3inClip_EVALREPORT.pdf Verified By: James L. Buckner P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL14210_R7_AE_9_ZeeLock_22ga_InsulSteelPurlins_3inClip_EVALREPORT.pdf Created by Independent Third Party: Yes |