| 42007.1 |
Comfort Shield Fixed Casement/Awning |
Vinyl Fixed Casement/Awning 71.5" x 71.5" 1-wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: Other: Configurations of glass shall conform to the current ASTM E1300 standard. Safety glass shall be used when required by code. |
Certification Agency Certificate FL42007_R2_C_CAC_CCL 411-H-1493-00.01.08.pdf Quality Assurance Contract Expiration Date 11/30/2027 Installation Instructions FL42007_R2_II_Anchor requirements in saltwater coastline areas.pdf FL42007_R2_II_Drawing 2021 digitally sealed.pdf Verified By: Warren W. Schaefer P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL42007_R2_AE_Drawing 2021 digitally sealed.pdf Created by Independent Third Party: Yes |
|
|
| 42007.2 |
Comfort Shield Fixed Casement/Awning |
Vinyl Fixed Casement/Awning 71.5" x 71.5" 2-wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: Other: Configurations of glass shall conform to the current ASTM E1300 standard. Safety glass shall be used when required by code. Reinforced mullion required. |
Certification Agency Certificate FL42007_R2_C_CAC_CCL 411-H-1493-04.05.09.pdf Quality Assurance Contract Expiration Date 12/05/2027 Installation Instructions FL42007_R2_II_Anchor requirements in saltwater coastline areas.pdf FL42007_R2_II_Drawing 2021 digitally sealed.pdf Verified By: Warren W. Schaefer P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL42007_R2_AE_Drawing 2021 digitally sealed.pdf Created by Independent Third Party: Yes |
|
|
| 42007.3 |
Comfort Shield Fixed Casement/Awning |
Vinyl Fixed Casement/Awning 59.5" x 59.5" 1-wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Other: Configurations of glass shall conform to the current ASTM E1300 standard. Safety glass shall be used when required by code. |
Certification Agency Certificate FL42007_R2_C_CAC_CCL 411-H-1493-15.16.17.pdf Quality Assurance Contract Expiration Date 08/16/2028 Installation Instructions FL42007_R2_II_Anchor requirements in saltwater coastline areas.pdf FL42007_R2_II_Drawing 2021 digitally sealed.pdf Verified By: Warren W. Schaefer P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL42007_R2_AE_Drawing 2021 digitally sealed.pdf Created by Independent Third Party: Yes |
|
|
| 42007.4 |
Comfort Shield Fixed Casement/Awning |
Casement/Awning 71.5" x 71.5" 2-wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: Other: Configurations of glass shall conform to the current ASTM E1300 standard. Safety glass shall be used when required by code. Reinforced mullion required. |
Certification Agency Certificate FL42007_R2_C_CAC_CCL 411-H-1491-40.41.42.pdf Quality Assurance Contract Expiration Date 08/16/2028 Installation Instructions FL42007_R2_II_Anchor requirements in saltwater coastline areas.pdf FL42007_R2_II_Drawing 2021 digitally sealed.pdf Verified By: Warren W. Schaefer P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL42007_R2_AE_Drawing 2021 digitally sealed.pdf Created by Independent Third Party: Yes |