| 42047.1 |
01: 26ga 1" Nail Strip over Plywood |
26ga (min) 1" nail strip standing seam panel over 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.5 Other: See report for details |
Installation Instructions FL42047_R5_II_26ga_1in_Nailstrip.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42047_R5_AE_26ga_1in_Nailstrip.pdf Created by Independent Third Party: Yes |
|
|
| 42047.2 |
02: 26ga 1.5" Snaplock over Plywood |
26ga (min) 1.5" Snaplock standing seam panel over 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116 Other: See report for details |
Installation Instructions FL42047_R5_II_26ga_150_Snaplock.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42047_R5_AE_26ga_150_Snaplock.pdf Created by Independent Third Party: Yes |
|
|
| 42047.3 |
03: 26ga 1.75" Snaplock over Plywood |
26ga (min) 1.75" Snaplock standing seam panel over 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-131 Other: See report for details |
Installation Instructions FL42047_R5_II_26ga_175_Snaplock.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42047_R5_AE_26ga_175_Snaplock.pdf Created by Independent Third Party: Yes |
|
|
| 42047.4 |
04: 29ga Rib panel over Plywood |
29ga (min) Rib panel over 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-161 Other: See report for details |
Installation Instructions FL42047_R5_II_29ga_Rib.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42047_R5_AE_29ga_Rib.pdf Created by Independent Third Party: Yes |
|
|
| 42047.5 |
05: Aluminum 1.5" Snaplock over Plywood |
Nominally 0.032" aluminum (or thicker) 1.5" Snaplock standing seam panel over 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-63.5 Other: See report for details |
Installation Instructions FL42047_R5_II_032Al_150_Snaplock.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42047_R5_AE_032Al_150_Snaplock.pdf Created by Independent Third Party: Yes |
|
|
| 42047.6 |
06: 29ga Rib panel over 1x4s on plywood |
29ga (min) Rib panel over 1x4s on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-161 Other: See report for details |
Installation Instructions FL42047_R5_II_29ga_Rib on 1x4s.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL42047_R5_AE_29ga_Rib on 1x4s.pdf Created by Independent Third Party: Yes |