| 4813.1 |
Loc-Seam |
Min 24 ga., max 16" wide standing seam roof panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +52.5/-52.5 Other: This compliance is not for HVHZ. Panels to be installed in accordance with applicable UL 580 constructions (238, 238A, 238B, 238C, 336, 435, 451, 487, or 567). Minimum installed roof slope is 0.25/12. Allowable load capacity assumes a factor of safety of 2. |
Certification Agency Certificate FL4813_R7_C_CAC_UL238_238A_238B_238C_336.pdf FL4813_R7_C_CAC_UL435_451_487_567.pdf Quality Assurance Contract Expiration Date 12/31/2023 Installation Instructions FL4813_R7_II_UL238_238A_238B_238C_336.pdf FL4813_R7_II_UL435_451_487_567.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 4813.2 |
Standing Seam 360 |
Min 24 ga., 24" wide standing seam roof panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +52.5/-52.5 Other: This compliance is not for HVHZ.
Panels to be installed in accordance with applicable UL 580 constructions (93 or 210A).
Minimum installed roof slope is 0.25/12. Allowable load capacity assumes a factor of safety of 2. |
Certification Agency Certificate FL4813_R7_C_CAC_UL93_210A.pdf Quality Assurance Contract Expiration Date 12/31/2023 Installation Instructions FL4813_R7_II_UL93_210A.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 4813.3 |
Standing Seam II |
Min 24 ga., 24" wide standing seam roof panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +52.5/-52.5 Other: This compliance is not for HVHZ.
Panels to be installed in accordance with applicable UL 580 constructions (93 or 210A).
Minimum installed roof slope is 0.25/12. Allowable load capacity assumes a factor of safety of 2. |
Certification Agency Certificate FL4813_R7_C_CAC_UL93_210A.pdf Quality Assurance Contract Expiration Date 12/31/2023 Installation Instructions FL4813_R7_II_UL93_210A.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |