| 37372.1 |
UBFLD 210100 |
Ultimate Bi-Fold Door 407-H-1146 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max. Size: 6382mm x 3035mm (251 1/4" x 119 1/2"), Max Panel Width: 41 1/16" Glass makeup, insulated glass comprised of two 4.7 mm tempered panes separated by an 14.0 mm metal spacer. Glass complies with ASTM E1300. Hardware, Multi point lock with deadbolt. |
Certification Agency Certificate FL37372_R1_C_CAC_1146.00.01.pdf Quality Assurance Contract Expiration Date 11/28/2026 Installation Instructions FL37372_R1_II_127465.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 37372.2 |
UBFLD 21080 |
Ultimate Bi-Fold Door 407-H-1146 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Max. Size: 6382mm x 2426mm (251 1/4" x 95 1/2"), Max Panel Width: 41 1/16" Glass makeup, insulated glass comprised of two 3.9 mm tempered panes separated by an 16.1 mm metal spacer. Glass complies with ASTM E1300 Hardware is Multi-Point Lock W/Deadbolt |
Certification Agency Certificate FL37372_R1_C_CAC_1146.02.03.pdf Quality Assurance Contract Expiration Date 12/20/2026 Installation Instructions FL37372_R1_II_127465.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 37372.3 |
UBFLD 36100 (O) |
Ultimate Bi-Fold Door 407-H-1146 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +55/-65 Other: Max. Size: 1140mm x 3035mm (44 7/8" x 119 1/2"), Max Panel Width: 41 1/16" Glass makeup, insulated glass comprised of two 4.7 mm tempered panes separated by an 14.0 mm metal spacer. Glass complies with ASTM E1300 Hardware Stationary Sill Bolt. |
Certification Agency Certificate FL37372_R1_C_CAC_1146.04.05.pdf Quality Assurance Contract Expiration Date 12/20/2026 Installation Instructions FL37372_R1_II_127487.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |