| 41812.1 |
01: 24ga 1.5" Nail Strip over Plywood |
24ga (min) 1.5" nail strip standing seam panel over 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116 Other: See report for details |
Installation Instructions FL41812_R2_II_24ga_1.5_Nailstrip_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41812_R2_AE_24ga_1.5_Nailstrip_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 41812.2 |
02: 24ga 1.5" Snap Lock over Plywood |
24ga (min) 1.5" snap lock standing seam panel over 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116 Other: See report for details |
Installation Instructions FL41812_R2_II_24ga_1.5_SnapLock_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41812_R2_AE_24ga_1.5_SnapLock_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 41812.3 |
03: 032 Aluminum 1" Mechanical Lock on Plywood |
Nominally 0.032" aluminum (or thicker) 1" mechanical lock standing seam panel on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101 Other: See report for details |
Installation Instructions FL41812_R2_II_032_1.0_Mechanical_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41812_R2_AE_032_1.0_Mechanical_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 41812.4 |
04: 24ga 1.0" Nail Strip on Plywood |
24ga (min) 1.0" nail strip standing seam panel over 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5 Other: See report for details |
Installation Instructions FL41812_R2_II_24ga_1.0_Nailstrip_plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41812_R2_AE_24ga_1.0_Nailstrip_plywood_nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 41812.5 |
05: 24ga 1.0" Snap Lock over Plywood |
24ga (min) 1.0" snap lock standing seam panel over 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-131 Other: See report for details |
Installation Instructions FL41812_R2_II_24ga_1.0_SnapLock_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41812_R2_AE_24ga_1.0_SnapLock_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 41812.6 |
06: 26ga 5V Crimp on Plywood |
26ga (min) 5V Crimp exposed fastener panel on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-156.5 Other: See report for details |
Installation Instructions FL41812_R2_II_26ga_5VCrimp_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41812_R2_AE_26ga_5VCrimp_plywood.pdf Created by Independent Third Party: Yes |