Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL41891-R4
Application Type Revision
Code Version 2026
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Kolbe Windows and Doors - Manawa
Address/Phone/Email 1211 Depot Street
Manawa, WI 54949
(715) 847-0736
karen.long@kolbewindows.com
 
Authorized Signature Karen Long
karen.long@kolbewindows.com
 
Technical Representative Nathan Bonikowske
Address/Phone/Email 1211 Depot Street
Manawa, WI 54949
(920) 596-2501
nbonikowske@kolbe-kolbe.com
 
Quality Assurance Representative
Address/Phone/Email
 
Category Exterior Doors
Subcategory Sliding Exterior Door Assemblies
 
Compliance Method Certification Mark or Listing
 
Certification Agency Window and Door Manufacturer Association
Validated By T.E. Lunn, PE, LLC
  Validation Checklist - Hardcopy Received
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA/CSA 101/I.S.2/A4402011
AAMA/WDMA/CSA 101/I.S.2/A4402017
ASTM E18862019
ASTM E19962020
TAS-201,202 & 2031994
 
Equivalence of Product Standards
Certified By

 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 07/01/2026
Date Validated 07/08/2026
Date Pending FBC Approval
Date Approved 07/09/2026
 
Summary of Products
FL # Model, Number or Name Description
41891.1 Forgent Complementary Multislide Door 143.5" x 95.5", OXX or XXO, w/screen, Non-impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +40/-40
 Other: Glass complies with the current ASTM E1300 standard; When water infiltration resistance is required of the doors, the positive design pressure shall be limited to +35 psf.
Certification Agency Certificate
 FL41891_R4_C_CAC_CCL AI-04969-D1 Rev.1.pdf
Quality Assurance Contract Expiration Date
 11/01/2028
Installation Instructions
 FL41891_R4_II_Anchor requirements in saltwater coastline areas.pdf
 FL41891_R4_II_Drawing 2012 sealed.pdf
 Verified By: Warren W. Schaefer, P.E. 44135
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41891_R4_AE_Drawing 2012 sealed.pdf
 Created by Independent Third Party: Yes
41891.2 Forgent Complementary Multislide Door 143.5" x 95.5", OXX or XXO, no screen, Non-impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +40/-40
 Other: Glass complies with the current ASTM E1300 standard; When water infiltration resistance is required of the doors, the positive design pressure shall be limited to +40 psf.
Certification Agency Certificate
 FL41891_R4_C_CAC_CCL AI-04969-D2.pdf
Quality Assurance Contract Expiration Date
 11/01/2028
Installation Instructions
 FL41891_R4_II_Anchor requirements in saltwater coastline areas.pdf
 FL41891_R4_II_Drawing 2012 sealed.pdf
 Verified By: Warren W. Schaefer, P.E. 44135
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41891_R4_AE_Drawing 2012 sealed.pdf
 Created by Independent Third Party: Yes
41891.3 Forgent Complementary Multislide Door 276" x 95.5", OXX-XXO, w/screen, Non-impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +30/-30
 Other: Glass complies with the current ASTM E1300 standard; When water infiltration resistance is required of the doors, the positive design pressure shall be limited to +15 psf.
Certification Agency Certificate
 FL41891_R4_C_CAC_CCL AI-05151-I1 Rev2.pdf
Quality Assurance Contract Expiration Date
 06/20/2029
Installation Instructions
 FL41891_R4_II_Anchor requirements in saltwater coastline areas.pdf
 FL41891_R4_II_Drawing 2012 sealed.pdf
 Verified By: Warren W. Schaefer, P.E. 44135
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41891_R4_AE_Drawing 2012 sealed.pdf
 Created by Independent Third Party: Yes
41891.4 Forgent Complementary Multislide Door 276" x 95.5", OXX-XXO, no screen, Non-impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +30/-30
 Other: Glass complies with the current ASTM E1300 standard; When water infiltration resistance is required of the doors, the positive design pressure shall be limited to +30 psf.
Certification Agency Certificate
 FL41891_R4_C_CAC_CCL AI-05151-I2.pdf
Quality Assurance Contract Expiration Date
 06/30/2029
Installation Instructions
 FL41891_R4_II_Anchor requirements in saltwater coastline areas.pdf
 FL41891_R4_II_Drawing 2012 sealed.pdf
 Verified By: Warren W. Schaefer, P.E. 44135
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41891_R4_AE_Drawing 2012 sealed.pdf
 Created by Independent Third Party: Yes
41891.5 Forgent Complementary Multislide Door 205.125" x 95.5", OXX-XXO, w/screen, Non-impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +45/-45
 Other: Glass complies with the current ASTM E1300 standard; When water infiltration resistance is required of the doors, the positive design pressure shall be limited to +25 psf.
Certification Agency Certificate
 FL41891_R4_C_CAC_CCL AI-05151-G1 Rev.1.pdf
Quality Assurance Contract Expiration Date
 06/17/2029
Installation Instructions
 FL41891_R4_II_Anchor requirements in saltwater coastline areas.pdf
 FL41891_R4_II_Drawing 2012 sealed.pdf
 Verified By: Warren W. Schaefer, P.E. 44135
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41891_R4_AE_Drawing 2012 sealed.pdf
 Created by Independent Third Party: Yes
41891.6 Forgent Complementary Multislide Door 205.125" x 95.5", OXX-XXO, no screen, Non-impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +45/-45
 Other: Glass complies with the current ASTM E1300 standard; When water infiltration resistance is required of the doors, the positive design pressure shall be limited to +35 psf.
Certification Agency Certificate
 FL41891_R4_C_CAC_CCL AI-05151-G2 Rev.1.pdf
Quality Assurance Contract Expiration Date
 06/17/2029
Installation Instructions
 FL41891_R4_II_Anchor requirements in saltwater coastline areas.pdf
 FL41891_R4_II_Drawing 2012 sealed.pdf
 Verified By: Warren W. Schaefer, P.E. 44135
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41891_R4_AE_Drawing 2012 sealed.pdf
 Created by Independent Third Party: Yes
41891.7 Forgent Complementary Multislide Door 143.5" x 95.5", OXX or XXO, w/screen, Impact
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-65
 Other: Glass complies with the current ASTM E1300 standard; (4.7mm Temp - 8.0mm SS - 3.9mm Ann .090" PVB 3.9mm Ann), Insulated Glazed, Impact Performance, Missile D, Wind Zone 4; When water infiltration resistance is required of the doors, the positive design pressure shall be limited to +60 psf.
Certification Agency Certificate
 FL41891_R4_C_CAC_CCL 22091, 22092 ASTM.pdf
 FL41891_R4_C_CAC_CCL 22091, 22092 TAS.pdf
 FL41891_R4_C_CAC_CCL 22091.pdf
Quality Assurance Contract Expiration Date
 06/30/2031
Installation Instructions
 FL41891_R4_II_Anchor requirements in saltwater coastline areas.pdf
 FL41891_R4_II_Drawing 2012A sealed.pdf
 Verified By: Warren W. Schaefer, P.E. 44135
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41891_R4_AE_Drawing 2012A sealed.pdf
 Created by Independent Third Party: Yes
41891.8 Forgent Complementary Multislide Door 143.5" x 95.5", OXX or XXO, no screen, Impact
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-65
 Other: Glass complies with the current ASTM E1300 standard; (4.7mm Temp - 8.0mm SS - 3.9mm Ann .090" PVB 3.9mm Ann), Insulated Glazed, Impact Performance, Missile D, Wind Zone 4; When water infiltration resistance is required of the doors, the positive design pressure shall be limited to +65 psf.
Certification Agency Certificate
 FL41891_R4_C_CAC_CCL 22091, 22092 ASTM.pdf
 FL41891_R4_C_CAC_CCL 22091, 22092 TAS.pdf
 FL41891_R4_C_CAC_CCL 22092.pdf
Quality Assurance Contract Expiration Date
 06/30/2031
Installation Instructions
 FL41891_R4_II_Anchor requirements in saltwater coastline areas.pdf
 FL41891_R4_II_Drawing 2012A sealed.pdf
 Verified By: Warren W. Schaefer, P.E. 44135
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41891_R4_AE_Drawing 2012A sealed.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex