| 41891.1 |
Forgent Complementary Multislide Door |
143.5" x 95.5", OXX or XXO, w/screen, Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Glass complies with the current ASTM E1300 standard; When water infiltration resistance is required of the doors, the positive design pressure shall be limited to +35 psf. |
Certification Agency Certificate FL41891_R3_C_CAC_CCL AI-04969-D1 Rev.1.pdf Quality Assurance Contract Expiration Date 11/01/2028 Installation Instructions FL41891_R3_II_Drawing 2012 sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL41891_R3_AE_Drawing 2012 sealed.pdf Created by Independent Third Party: Yes |
|
|
| 41891.2 |
Forgent Complementary Multislide Door |
143.5" x 95.5", OXX or XXO, no screen, Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Glass complies with the current ASTM E1300 standard; When water infiltration resistance is required of the doors, the positive design pressure shall be limited to +40 psf. |
Certification Agency Certificate FL41891_R3_C_CAC_CCL AI-04969-D2.pdf Quality Assurance Contract Expiration Date 11/01/2028 Installation Instructions FL41891_R3_II_Drawing 2012 sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL41891_R3_AE_Drawing 2012 sealed.pdf Created by Independent Third Party: Yes |
|
|
| 41891.3 |
Forgent Complementary Multislide Door |
276" x 95.5", OXX-XXO, w/screen, Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: Glass complies with the current ASTM E1300 standard; When water infiltration resistance is required of the doors, the positive design pressure shall be limited to +15 psf. |
Certification Agency Certificate FL41891_R3_C_CAC_CCL AI-05151-I1 Rev2.pdf Quality Assurance Contract Expiration Date 06/20/2029 Installation Instructions FL41891_R3_II_Drawing 2012 sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL41891_R3_AE_Drawing 2012 sealed.pdf Created by Independent Third Party: Yes |
|
|
| 41891.4 |
Forgent Complementary Multislide Door |
276" x 95.5", OXX-XXO, no screen, Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: Glass complies with the current ASTM E1300 standard; When water infiltration resistance is required of the doors, the positive design pressure shall be limited to +30 psf. |
Certification Agency Certificate FL41891_R3_C_CAC_CCL AI-05151-I2.pdf Quality Assurance Contract Expiration Date 06/30/2029 Installation Instructions FL41891_R3_II_Drawing 2012 sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL41891_R3_AE_Drawing 2012 sealed.pdf Created by Independent Third Party: Yes |
|
|
| 41891.5 |
Forgent Complementary Multislide Door |
205.125" x 95.5", OXX-XXO, w/screen, Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +45/-45 Other: Glass complies with the current ASTM E1300 standard; When water infiltration resistance is required of the doors, the positive design pressure shall be limited to +25 psf. |
Certification Agency Certificate FL41891_R3_C_CAC_CCL AI-05151-G1 Rev.1.pdf Quality Assurance Contract Expiration Date 06/17/2029 Installation Instructions FL41891_R3_II_Drawing 2012 sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL41891_R3_AE_Drawing 2012 sealed.pdf Created by Independent Third Party: Yes |
|
|
| 41891.6 |
Forgent Complementary Multislide Door |
205.125" x 95.5", OXX-XXO, no screen, Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +45/-45 Other: Glass complies with the current ASTM E1300 standard; When water infiltration resistance is required of the doors, the positive design pressure shall be limited to +35 psf. |
Certification Agency Certificate FL41891_R3_C_CAC_CCL AI-05151-G2 Rev.1.pdf Quality Assurance Contract Expiration Date 06/17/2029 Installation Instructions FL41891_R3_II_Drawing 2012 sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL41891_R3_AE_Drawing 2012 sealed.pdf Created by Independent Third Party: Yes |
|
|
| 41891.7 |
Forgent Complementary Multislide Door |
143.5" x 95.5", OXX or XXO, w/screen, Impact |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: Glass complies with the current ASTM E1300 standard; (4.7mm Temp - 8.0mm SS - 3.9mm Ann .090" PVB 3.9mm Ann), Insulated Glazed, Impact Performance, Missile D, Wind Zone 4; When water infiltration resistance is required of the doors, the positive design pressure shall be limited to +60 psf. |
Certification Agency Certificate FL41891_R3_C_CAC_CCL 22091, 22092 ASTM.pdf FL41891_R3_C_CAC_CCL 22091, 22092 TAS.pdf FL41891_R3_C_CAC_CCL 22091.pdf Quality Assurance Contract Expiration Date 06/30/2031 Installation Instructions FL41891_R3_II_Drawing 2012A sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL41891_R3_AE_Drawing 2012A sealed.pdf Created by Independent Third Party: Yes |
|
|
| 41891.8 |
Forgent Complementary Multislide Door |
143.5" x 95.5", OXX or XXO, no screen, Impact |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: Glass complies with the current ASTM E1300 standard; (4.7mm Temp - 8.0mm SS - 3.9mm Ann .090" PVB 3.9mm Ann), Insulated Glazed, Impact Performance, Missile D, Wind Zone 4; When water infiltration resistance is required of the doors, the positive design pressure shall be limited to +65 psf. |
Certification Agency Certificate FL41891_R3_C_CAC_CCL 22091, 22092 ASTM.pdf FL41891_R3_C_CAC_CCL 22091, 22092 TAS.pdf FL41891_R3_C_CAC_CCL 22092.pdf Quality Assurance Contract Expiration Date 06/30/2031 Installation Instructions FL41891_R3_II_Drawing 2012A sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL41891_R3_AE_Drawing 2012A sealed.pdf Created by Independent Third Party: Yes |