| 16743.1 |
K8206AMD Hurricane Louver |
6" Deep Combination Louver-Damper, Horizontal Blade, Extruded Aluminum, High Velocity Wind Driven Rain Resistant, Impact & Pressure Resistant |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +110/-110 Other: Allowable Stress Design (ASD). Rated for AMCA 540 Basic Protection Missile Impact Level D (50 fps) without TAS 203 Cyclic. Rated for TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Passed AMCA 550 with Blades Fully Closed. Substrates Include: Concrete (Non-Cracked), Grout Filled CMU, Steel, Aluminum & Wood. |
Installation Instructions FL16743_R5_II_FPA 16743 K8206AMD PE Eval Report 2024-01-05.pdf Verified By: Robert Nangia 69555 Created by Independent Third Party: Yes Evaluation Reports FL16743_R5_AE_FPA 16743 K8206AMD PE Eval Report 2024-01-05.pdf Created by Independent Third Party: Yes |