| 16744.1 |
Ultra French Inswing Door |
74 x 123, Impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +40/-40 Other: 5-pt lock active panel and 2-pt handle activated shoot bolt lock system passive panel; Glass complies with the current ASTM E1886/1996 standard (Lami 30:3.9mm T - 8.0mm SS - 3.9mm Ann .090” PVB 3.9mm Ann glass), Dual Glazed, Impact Performance, Missile D, Wind Zone 4; (Lami 6:3.9mm Ann .090 PVB 3.9mm Ann) |
Certification Agency Certificate FL16744_R4_C_CAC_21036, 21037, 21039 CCL.pdf Quality Assurance Contract Expiration Date 04/04/2033 Installation Instructions FL16744_R4_II_21036, 21037, 21039 String.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 16744.2 |
Ultra Series French Inswing Door |
74-3/16" x 98-23/32", Impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +40/-40 Other: 5-pt lock active panel and 2-pt handle activated shoot bolt lock system passive panel; Glass complies with the current ASTM E1300 standard (3.9mm T - 8.0mm SS - 3.9mm Ann .090” SGP 3.9mm Ann), Insulated Glazed, Impact Performance, Missile D, Wind Zone 3; Doors are available w/& w/o raised panels in designs both w/glass & full raised panels (no glass), in accordance w/the following guidelines – maximum raised panel height 62”, maximum mid/cross rail length 28-1/8”; Alum clad frame |
Certification Agency Certificate FL16744_R4_C_CAC_23044 - 23045 recert 13068 - 13067 CCL.pdf Quality Assurance Contract Expiration Date 03/26/2034 Installation Instructions FL16744_R4_II_13067-68 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 16744.3 |
Ultra Series French Inswing Door |
74-3/16" x 98-23/32", Impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +40/-40 Other: 5-pt lock active panel and 2-pt handle activated shoot bolt lock system passive panel; Glass complies with the current ASTM E1300 standard (3.9mm Ann .090” SGP 3.9mm Ann), Single Glazed, Impact Performance, Missile D, Wind Zone 3; Doors are available w/& w/o raised panels in designs both w/glass & full raised panels (no glass), in accordance w/the following guidelines – maximum raised panel height 62”, maximum mid/cross rail length 28-1/8”; Alum clad frame |
Certification Agency Certificate FL16744_R4_C_CAC_23044 - 23045 recert 13068 - 13067 CCL.pdf Quality Assurance Contract Expiration Date 03/26/2034 Installation Instructions FL16744_R4_II_13067-68 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |