| 48382.1 |
01: 22ga MRS 2500 on plywood |
22ga (min) MRS 2500 mechanical seam panel on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-175 Other: See evaluation report. |
Installation Instructions FL48382_R0_II_22ga_2500_plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL48382_R0_AE_22ga_2500_plywood_nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 48382.2 |
02: 26ga 1" Nailstrip on plywood |
26ga (min) 1" Nailstrip panel on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-78.5 Other: See evaluation report. |
Installation Instructions FL48382_R0_II_26ga_nailstrip_plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL48382_R0_AE_26ga_nailstrip_plywood_nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 48382.3 |
03: 24ga 1" Nailstrip on OSB |
24ga (min) 1" Nailstrip panel on 7/16" (min) OSB |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-63.5 Other: See evaluation report. |
Installation Instructions FL48382_R0_II_24ga_nailstrip_osb_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL48382_R0_AE_24ga_nailstrip_osb_nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 48382.4 |
04: 032 aluminum MRS 1500 on OSB |
Nominally 0.032" aluminum or thicker MRS 1500 on 7/16" (min) OSB |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5 Other: See evaluation report. |
Installation Instructions FL48382_R0_II_032Al_1500Mechanical_OSB_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL48382_R0_AE_032Al_1500Mechanical_OSB_nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 48382.5 |
05: 032 aluminum S1000 on plywood |
Nominally 0.032" aluminum or thicker MRS 1000 on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101 Other: See evaluation report. |
Installation Instructions FL48382_R0_II_032_S1000_plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL48382_R0_AE_032_S1000_plywood_nonHVHZ.pdf Created by Independent Third Party: Yes |