| 4838.1 |
Loc-Seam |
Min 24 ga., 16" wide standing seam roof panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-157.5 Other: Uplift load of 157.5 psf at clip and S-5-U Mini clamp spacing of 24" o.c. |
Installation Instructions FL4838_R7_II_EvaluationReportC2729_4.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL4838_R7_AE_EvaluationReportC2729_4.pdf Created by Independent Third Party: Yes |
|
|
| 4838.2 |
R-Panel |
Min. 26 ga., 36" wide, through fastened panel over open supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limitations and load tables. |
Installation Instructions FL4838_R7_II_EvaluationReportC2729_5.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL4838_R7_AE_EvaluationReportC2729_5.pdf Created by Independent Third Party: Yes |
|
|
| 4838.3 |
SS360 |
Min 24 ga., 24" wide standing seam roof panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-66.8 Other: Uplift load of 66.8 psf at clip spacing of 24" o.c. |
Installation Instructions FL4838_R7_II_EvaluationReportC2729_6.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL4838_R7_AE_EvaluationReportC2729_6.pdf Created by Independent Third Party: Yes |