| 48342.1 |
01: 032 Aluminum 450SL on plywood |
0.032 aluminum (nom, or thicker) 450SL on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-161 Other: See evaluation report. |
Installation Instructions FL48342_R0_II_32Al_450SL_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL48342_R0_AE_32Al_450SL_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 48342.2 |
02: 26ga 450SL on plywood |
26ga (min) 450SL on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-176 Other: See evaluation report. |
Installation Instructions FL48342_R0_II_26ga_450SL_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL48342_R0_AE_26ga_450SL_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 48342.3 |
03: 032 Aluminum 550SL on plywood |
0.032 aluminum (nom, or thicker) 550SL on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-176 Other: See evaluation report. |
Installation Instructions FL48342_R0_II_32Al_550SL_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL48342_R0_AE_32Al_550SL_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 48342.4 |
04: 26ga 550SL on plywood |
26ga (min) 550SL on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-128.5 Other: See evaluation report. |
Installation Instructions FL48342_R0_II_26ga_550SL_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL48342_R0_AE_26ga_550SL_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 48342.5 |
05: 7mm Zinc 675SL on OSB |
7mm (nom, or greater) 675SL on 1/2" (min) OSB |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101 Other: See evaluation report. |
Installation Instructions FL48342_R0_II_Zn_675SL_OSB im.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL48342_R0_AE_Zn_675SL_OSB im.pdf Created by Independent Third Party: Yes |
|
|
| 48342.6 |
06: 032 Aluminum 675SL on plywood |
0.032 aluminum (nom, or thicker) 675SL on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-228.5 Other: See evaluation report. |
Installation Instructions FL48342_R0_II_32Al_675SL_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL48342_R0_AE_32Al_675SL_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 48342.7 |
07: 032 Aluminum 675SL on steel deck |
0.032 aluminum (nom, or thicker) 675SL on 22ga (min) steel deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5 Other: See evaluation report. |
Installation Instructions FL48342_R0_II_32Al_675SL_BDeck.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL48342_R0_AE_32Al_675SL_BDeck.pdf Created by Independent Third Party: Yes |
|
|
| 48342.8 |
08: 24ga 675SL on plywood |
24ga 675SL on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-243.5 Other: See evaluation report. |
Installation Instructions FL48342_R0_II_24ga_675SL_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL48342_R0_AE_24ga_675SL_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 48342.9 |
09: 24ga 675SL on steel deck |
24ga 675SL on 22ga (min) steel deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-161 Other: See evaluation report. |
Installation Instructions FL48342_R0_II_24ga_675SL_BDeck.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL48342_R0_AE_24ga_675SL_BDeck.pdf Created by Independent Third Party: Yes |