| 8651.1 |
Rhino Rib 1.0 Nail Strip |
24 Ga. 16" Wide over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5PSF Other: -59.75 psf @ 16" o.c. fastener spacing. -101.0 psf 6 3/4" o.c. fastener spacing. -153.5 psf @ 6 3/4" o.c. fastener spacing. Install per Manufacturers details. Not for use in HVHZ Zones. |
Installation Instructions FL8651_R6_II_RSS 2023 FL 8651 AMW CONTRACTING INC REPORT AND DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8651_R6_AE_RSS 2023 FL 8651 AMW CONTRACTING INC REPORT AND DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 8651.2 |
Rhino Rib 1.5 Snap Lock |
24 Ga. 16" Wide over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0PSF Other: -86.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" o.c. clip spacing. -116.0 psf @ 6" o.c. clip spacing. Install per Manufacturers Details. For use in HVHZ Zones. |
Installation Instructions FL8651_R6_II_RSS 2023 FL 8651 AMW CONTRACTING INC REPORT AND DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8651_R6_AE_RSS 2023 FL 8651 AMW CONTRACTING INC REPORT AND DETAILS.pdf Created by Independent Third Party: Yes |